WEG CVW300 Guia De Instalacion página 12

Convertidor de frecuencia para tracción eléctrica
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Variable Speed Drive for Electric Traction
Seq.
Action/Result
- In this mom e nt the O r ie nte d S ta r t-
uproutine is initiated and the "CONF"
status is indicated at the keypad (HMI).
- The parameter "P0000 – Access to
7
Parameters" is selected. Change the
password to set the remaining parameters
if necessary.
- Press the
key to the next parameter.
- If necessary, change "P0296 – Battery
Rated Voltage". This change will affect
8
P0151, P0185, and P0400.
- Press the
key to the next parameter.
- Set parameter "P0202 – Typeof Control"
pressing "ENTER/MENU". Press the
key to select the desired option: "[1] =
Sensorless" or "[2] = Encoder". This
modification resets the content of P0410.
Then, press "ENTER/MENU". There are
9
three options to exit the oriented start-up:
1 - Running the Self-tunning.
2 - Manual settings of parameters from
P0409 to P0413.
3 - Changing P0202 from vector to scalar.
- Press the
key to the next parameter.
- If necessary, change "P0398 – Motor
Service Factor" parameter. This change
10
will affect the current and the time of the
motor overload protection operation.
- Press the
key to the next parameter.
- If necessary, change "P0400 – Motor
Rated Voltage" parameter. This change
11
corrects the output voltage by the factor
"x = P0400/ P0296".
- Press the
key to the next parameter.
- If necessary, change "P0401 – Motor
Rated Current" " parameter. This change
12
will affect P0156, P0157, P0158 and P0410.
- Press the
key to the next parameter.
- If necessary, change "P0404 – Motor
Rated Power" parameter. This change
13
will affect P0410.
- Press the
key to the next parameter.
- If necessary, change "P0403 – Motor
Rated Frequency " parameter. This
14
change will affect P0402.
key to the next parameter.
- Press the
- If necessary, change "P0402 – Motor
Rated Speed". This change will affect
15
P0122 to P0131, P0135, P0182, P0208,
P0288 and P0289.
- Press the
key to the next parameter.
- If necessary, change "P0405 – Encoder
Pu l s e s N u m b e r " ac c ording to the
16
encoder model.
- Press the
key to the next parameter.
12 | CVW300
Display Indication
Seq.
- In this moment the keypad presents
17
- Pre s s BAC K / E S C key to f inis h the
18
- Press BACK/ESC key again to get back
Return
Advance
Action/Result
the option to perform "Self-tunning".
The Self-tunning should be performed
whenever it is possible. Press "ENTER/
MENU" key to access parameter P0408
and press
to select the desired
option. Then, press "ENTER/MENU"
to start the Self-tunning. The keypad
will show "CONF" and "RUN"status
simultaneously during the self-tunning.
At the end of the self-tuning, the "RUN"
status is automatically erased and the
content of P0408 automatically goes
back to the.
start-up routine.
to the monitoring mode.
Figure 11: Start-up Oriented to the vector mode
Display Indication
Index
Tabla de contenido
loading

Tabla de contenido