37
CHOKE ELECTRODES
After removing the cover, detach the high-tension cables from the transformer side, remove the photo resistance
1, unscrew the connector that hooks the fuel line to the choke 3, (there are two 2 connectors for ECO 30/2 –
Eco 40/2), loosen the screws 4 and, turning the flange anti-clockwise, remove the flange-choke-deflector-
electrode assembly.
Remove the screws 5, in order to remove the deflector, and the screws 6 to remove the electrodes. The choke
may be cleaned adequately by removing the filter and cleaning inside the spray nozzle and jet with gasoline
and a light oil rinse. Re-assemble all parts carefully with special attention to the positioning of the electrodes-
deflector.