4. Increase the Static Stimulation Level by pressing and releasing the Stimulation Level Button within 5
seconds of the previous series of fl ashes.
5. After setting the Static Stimulation Level, replace the cover to protect the Stimulation Level Button.
The Static Stimulation levels increase in strength from 1 to 6. Pushing the Stimulation Level Button
while the Receiver Collar is on level 6 will cause the Receiver Collar to revert to level 1. Refer to the
Function and Response Table to choose the Static Stimulation level that best fi ts your pet.
The Receiver LED Indicator Light acts as a low battery indicator, fl ashing every 4 to 5 seconds when
replacement is required.
Battery Contact Verifi cation
Remove Receiver Collar from your pet. Press the button and verify that the LED light illuminates. If
the LED light does not come on remove the battery. Locate the metal tabs in the battery well. Gently
lift the tabs to ensure that the battery will make good contact. Replace the battery into the Receiver
Collar. Press the button and check that the LED light illuminates.
Indicator
Static Stimulation
Light
Response
1 Flash
2 Flashes
3 Flashes
4 Flashes
5 Flashes
6 Flashes
Flashes once
every 4 to 5
seconds
Over Stimulation Protection
If your pet enters the Boundary Zone or continues anywhere beyond the Pet Area, this feature limits
the Static Stimulation duration to 30 seconds.
In the unlikely event that your pet leaves the Pet Area, he will not receive a Static Stimulation upon
return to the Pet Area.
Function and Response Table
Receiver Collar Function
Level
1
No Static Stimulation,
2
Low Static Stimulation
3
Medium-Low Static Stimulation
4
Medium Static Stimulation
5
Medium-High Static Stimulation Average or High Energy
6
High Static Stimulation
Indicates Low Battery
www.petsafe.net
Tone Only
Temperament of Pet
Timid
Timid or Average
Average Energy
High Energy