The temperature display serves to:
Show the temperature of the pro-
duct inside the tank.
In
Evo/Super
the
and
sistency of the product can be re-
gulated. See pg 17
View temperature
The temperature display shows the temperature of the product in the tank cyclically (every 3
seconds).
To see which tank is referred to with the temperature reading, it is necessary to check which
decimal point is being shown:
-2
If the decimal point viewed is on
the left, the temperature reading
refers to the tank 1.
Alarms
In case of failure, the display will show the following alarm messages:
ALARM
Standard Model
A1
Tank 1 probe disconnected.
A2
Tank 1 probe short circuit.
A3
Tank 2 probe disconnected.
A4
Tank 2 probe short circuit.
A5
Tank 3 probe disconnected.
A6
Tank 3 probe short circuit.
5.Warnings and
indications
machines using
keys, the con-
-2
If the decimal point viewed is
in the centre, the temperature
reading refers to the tank 2.
1
1
2
Tank probe short circuit.
Tank probe disconnected.
The product in the tank is too chilled.
Switch off the machine. Wait for the product to warm a little.Switch the machi-
ne again and reduce the consistency of the product. (see pg.17)
The lid on the tank is not in position.
Reposition the lid on the tank (see pg.11). If the problem persists after reposi-
tioning the lid, contact the specialist technician.
The mixer does not turn.
Failure in the motor, cabling or electronic board. Contact the technician.
5.1 Temperature display
Show information regarding the
functions of the machine.
If the decimal point viewed is on
the right, the temperature rea-
ding refers to the tank 3.
1
2
3
Model
Evo/Super
Temperature display
-2
15