CoDE
possIBlE CAusE
4
Fuse blown, circuit breaker tripped
5
Tank pressure exceeds pressure switch cut-in pressure
6
Pressure release valve on pressure switch has not
unloaded head pressure
possIBlE solutIon
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker
with higher rating than that specified for your particular
branch circuit.
. Check for proper fuse. Use only a time delay fuse.
. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
Motor will start automatically when tank pressure drops
below cut-in pressure of pressure switch.
Set the On/Off switch to OFF. If the valve does not open,
replace switch. Contact a D
a D
WALT authorized service center.
e
WALT factory service center or
e