BURNER CONNECTION TO THE BOILER
ASSEMBLING THE HEAD UNIT
Make sure that the combustion head penetrates the furnace by the
amount specified by the boiler manufacturer .
Prior to installing the burner in the boiler, make sure the nozzle is
suitable for the power required, if this is not the case, replace it
following the instructions provided in the diagram стр. 15
For the handling of the burner, it is recommended to use a suitable
hoisting equipment to be anchored to the eyebolts shown in figure
0002937170.
Anchor the burner to the boiler door as follows:
•
Place the two insulating seals (B) on the burner connection
flange (A)
•
Anchor the flange (A) to the boiler (C) with the stud bolts,
washers and nuts provided (D).
Seal the space between the burner sleeve and the hole on
the refractory material inside the boiler door completely with
suitable material.
ELECTRICAL CONNECTIONS
It is recommended that all connections are performed with electrical
flexible wires. Power lines must be outdistanced from the hot parts.
Check that the power line to which the device is connected is pow-
ered with voltage values and frequency suitable for the burner. Make
sure that the main line, the relevant switch with fuses (essential)
and the possible limiter are suitable to stand the maximum current
absorbed by the burner.
For more details, see the relevant wiring diagrams for each single
burner.
8 / 28
0006081557_201310