Adjust Water Discharge
1. Screw the hose adapter onto the pump's water outlet and insert the hose on
2. Adjust the water jet for desired strength with the regulator.
Connect to the mains power
Never operate the pump without the filter housing. The filter housing protects the
pump from coarse debris that can block the pump.
For dry setup without filter housing, ensure that the pump cannot suction in any
pollutants or foreign objects. These could damage the pump.
1. Connect the pump to the mains power. The pump switches on automatically.
2. Pull out the power plug to switch off the pump.
6. Maintenance/Cleaning
– Follow the safety instructions (section 4).
– Clean the pump as required, this means when the pump's performance
1. Unplug power plug.
2. Pull off the filter housing.
3. Turn water intake to the left, until the water intake can be pulled out.
4. Pull rotor out
5. Clean all individual parts with a soft brush under flowing water. Check the
6. Insert rotor.
7. Place water intake on the unit, as described in the "Adjust water intake",
8. Fit the filter housing on.
7. Wintering
– Take the pump out of the water.
– Thoroughly clean the pump (section 6).
– Store the pump in a frost-free location in a container filled with water. This
– Never submerge the power plug!
– Before placing the pump in service again: Check all parts for damage, particu-
8. Troubleshooting
Attention: Follow the safety instructions (section 4).
– Never open the motor housing under any circumstances.
– The pump's cable cannot be replaced. If the cable is damaged, then the pump
12
Neptun Export.p65
GB
Operating instructions
the hose piece.
decreases.
The rotor is attached with a relatively strong magnet. Carefully pull out the
rotor by one of its plastic wings.
rotor for damages and replace if necessary.
section and tighten.
prevents the hardening of dirt and the gaskets remain intact.
larly the cords.
needs to be disposed of.
12
GB
06.01.2004, 13:21