Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Cleaning metal grease filters
These can be washed in the dishwasher, and need to
be cleaned whenever the S1 Led comes on or at least
once every 2 months of use, or more frequently if use is
particularly intensive.
Resetting the Grease Filter Alarm
• Turn the Lights and the Hood off.
• Press T3 and hold for at least 3 seconds, until LED
flashes three times in confirmation.
Cleaning the Filters
• Open the Panel.
• Remove the Filters one at a time, pushing them to-
wards the back of the unit and at the same time pulling
downward.
• Wash the Filters without bending them, and leave them
to dry completely before replacing. (If the surface of
the filter changes color as time goes by, this will have
absolutely no effect on the efficiency of the filter itself.)
• Replace the grease filters, taking care to ensure that
the handle faces forward
• Close the Panel.
• 4 Filters - 48" model, 3 Filters - 36" model.
Replacing Activated Charcoal Filter
They cannot be washed or regenerated, and must be
changed when led S1 starts to flash, or at least once every
6 months. The Alarm signal, if it has been activated, only
appears when the Hood Blower is turned on.
Resetting the alarm signal
• Turn the Lights and the Hood Blower off.
• Press T3 and hold for at least 3 seconds, until LED
flashes three times in confirmation.
Cleaning the Filters
• Open the Panel.
• Remove the Metal Grease Filter.
• Remove the saturated Activated Charcoal Filters, as
indicated (A).
• Fit the new Filters, as indicated (B).
• Replace the Metal grease filters.
• Close the Panel.

Lighting unit

• LED lights must be replaced by Faber factory authorized
service.
27
A
B
Tabla de contenido
loading