MAINTENANCE

GREASE FILTER

The filter must be cleaned every 2 months of operation, or
more frequently for particularly heavy usage, and can be
washed in a dishwasher.
CLEANING METAL SELF-SUPPORTING GREASE
FILTER
• Open the lighting unit by pulling on the notch.
• Remove the filter one by one pushing it towards the
back side of the hood unit and simultaneously pulling
downwards.
• Any kind of bending of the filter has to be avoided when
washing it. Before fitting it again into the hood make sure
that it is completely dry.
• When fitting the filter into the hood pay attention that
they are mounted in correct position the handle facing
outwards.
• Replace the lighting unit.

ACTIVATED CHARCOAL FILTER

(Recirculation Version)
This cannot be washed or regenerated, and must be
changed approximately once every 4 months, or more
frequently in the case of particularly intensive use.
CHANGING
• Open the light unit.
• Remove grease filter.
• Remove the saturated Activated Charcoal Filters, as in-
dicated (A).
• Fit the new Filters, as indicated (B).
• Fit the anti-grease filter and the Light Unit back into po-
sition.

LIGHTING UNIT

• For replacement contact technical support ("to pur-
chase contact technical support").