Cleaning metal grease filters
They can be washed in the dishwasher, and need to be cleaned
whenever the FG sign appears on the display or at least once every
2 months use, or more frequently if use is particularly intensive.
Resetting the alarm signal
• Turn the Lights and the Suction motor off, then disable the 24h
function, if enabled.
• Press button E (see the paragraph on Use).
Cleaning the Filters
• Remove the Filters one at a time, pushing them towards the back
of the unit and at the same time pulling downward.
• Wash the Filters without bending them, and leave them to dry
completely before replacing. (If the surface of the filter changes
color as time goes by, this will have absolutely no effect on the
efficiency of the filter itself.)
• Replace, taking care to ensure that the handle faces forwards.
• No water can be present in filters before installing back in hood.
Replacing Activated Charcoal Filter
It cannot be washed or regenerated, and must be changed when
the FC symbol on the display appears, or at least once every 4
months. The Alarm signal, if it has been activated, only appears
when the Suction motor is turned on.
Resetting the alarm signal
• Turn the Lights and the Suction motor off, then disable the 24h
function, if enabled.
• Press button E (see the paragraph on Use).
Cleaning the Filters
• Remove the Filters one at a time, pushing them towards the back
of the unit and at the same time pulling downward.
• Remove the saturated charcoal filter by releasing the fixing hooks.
• Fit the new filter and fasten it in its correct position.
• Replace, taking care to ensure that the handle faces forwards.
• CAUTION: When used in recirculation mode, to Reduce
the Risk of Fire and Shock use only conversion kit Model
FILTER2.
Lighting unit
• LED lights must be replaced by Faber factory authorized service.
18