46 | WBE 5210 | Decommissioning

13. Decommissioning

13.1

Temporary shutdown

In the event of lengthy periods of non-use:
Unplug the electrical connection.
Unfasten the compressed air connection.
13.2

Change of location

If the WBE 5210 is passed on, all the documentation
included in the scope of delivery must be handed over
together with the unit.
The WBE 5210 is only ever to be transported in the
original or equivalent packaging.
Unplug the electrical connection.
Heed the notes on initial commissioning.
Unfasten the compressed air connection.
Bolt the WBE 5210 back onto the pallet.
13.3

Disposal and scrapping

13.3.1

Substances hazardous to water

!
Oils and greases as well as refuse containing oil and
grease (e.g. filters) represent a hazard to water.
1. Substances hazardous to water must not be allowed
to enter the sewage system.
2. Substances hazardous to water must be disposed of
in accordance with the applicable regulations.
13.3.2

WBE 5210 and accessories

1. Disconnect the WBE 5210 from the mains and de-
tach the power cord.
2. Dismantle the WBE 5210 and sort out and dispose
of the different materials in accordance with the ap-
plicable regulations.
The WBE 5210 is subject to the European
directive 2002/96/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of the WBE 5210 prevents
environmental pollution and possible health
hazards.
|
1 695 654 697
2010-11-19

14. Technical data

14.1

WBE 5210

Function
Passenger vehicle wheel
balancing speed
Commercial vehicle wheel
balancing speed
Passenger vehicle wheel
measurement resolution
Commercial vehicle wheel measu-
rement resolution
Noise level
Power output
Voltage
Degree of protection
Pneumatic connection
i
The unbalance is indicated by a 3-digit display. The
unit - ounces (oz) or grams (g) - can be selected by
way of the <MENU> key (refer to Section 10).
14.2

Dimensions and weight

Function
WBE 5210 (H x W x D) max.
Weight
14.3

Application range

Function
Rim width
Rim diameter
Maximum wheel diameter
Maximum wheel width
Maximum wheel weight
Maximum lift height
Specification
190 U/min 50 Hz /
230 U/min 60 Hz
42 - 100 U/min
1/5 g (0.01/0.25 oz)
10/50 g (0.1/1.0 oz)
< 75 dB
0,7 kW
Depending on voltage
ordered
(refer to rating plate)
IP 22
800 - 1200 kPa (8-12 bar)
Specification
1950 x 2000 x 1350 mm
183 kg
min – max
1" – 20"
10" – 30"
1200 mm
650 mm
160 kg
440 mm
Robert Bosch GmbH
Tabla de contenido
loading