Frigo
6
Fault messages
Faults in the cooling system are shown on the display.
Display text
Cause
P1
The room temperature sensor is
defective.
P2
The evaporator sensor is defec-
tive.
Maintenance is due.
The
symbol
illuminates.
HA
High temperature alarm. The set
target temperature was not
reached.
LA
Low temperature alarm. The set
target temperature was not
reached.
Only for standby
A fault has occurred during
cooling with an
standby cooling operation.
electric motor:
An acoustic signal
sounds.
The temperature in the interior
The
symbol
of the cooling system has
illuminates.
exceeded or fallen below the
target temperature.
I
NOTE
If "PoF" appears on the display, this only means that the keypad is
locked. It needs to be unlocked (see chapter "Locking and unlocking
the keypad" on page 12).
EN
Result/measure
The cooling system switches off auto-
matically. Call the service hotline.
The cooling system continues to run,
but the fault remains indicated on the
display. Call the service hotline.
The cooling system continues to
operate. However, the message con-
tinues to be shown on the display.
Call the service hotline.
During maintenance, the operating
hours are reset.
Switch off the cooling system. Call
the service hotline.
Switch off the cooling system. Call
the service hotline.
See chapter "Troubleshooting" on
page 22.
Call the service hotline and provide a
detailed description of the fault.
Fault messages