7 TECHNICAL SPECIFICATIONS
Power supply voltage U1 (50/60Hz)
Slow blow line fuse
Maximum input power (KVA)
Maximum input power (KW)
Power factor PF
Max. input current I1max
Effective current I1eff
Duty factor (x=25°C)
(x=60%)
(x=100%)
Duty factor (x=40°C)
(x=60%)
(x=100%)
Adjustment range I2
Step
Open circuit voltage Uo
IP Protection rating
Insulation class
Dimensions (lxdxh)
Weight
Power supply cable
Manufacturing Standards
Wire feeder rated powe
No rolls
Standard roller
Tractable rollers
Wire feed speed
Wire feed button
Gas test button
Synergic programs
Steel rolls
Connector for Push-Pull torch
34
NEOMIG 3500
3x230/400Vac ±15%
35/20A
16.6 KVA
15kW
0.96
23.9A
15.1A
(x=40%) 350A
320A
260A
(x=35%) 350A
300A
240A
30-380A
3x10
50V
IP21S
H
1060x400x780 mm
123 Kg.
4x6 mm2
EN 60974-1
EN 60974-5
EN 60974-10
90W
2 (4)
1.0-1.2 (STD)
0.6-0.8-1.0-1.2-1.6 solid wire
0.8-1.0-1.2-1.6 aluminium wire
1.2-1.4-1.6-2.0-2.4 flux-core wire
1.5÷22 m/min.
yes
yes
yes
yes
no
NEOMIG 4500
3x230/400Vac ±15%
50/30A
24 KVA
22.9kW
0.96
34.8A
22A
(x=45%) 450A
390A
320A
(x=40%) 450A
370A
300A
30-480A
3x10
50V
IP21S
H
1060x400x780 mm
139 Kg.
4x6 mm2
EN 60974-1
EN 60974-5
EN 60974-10
90W
2 (4)
1.0-1.2 (STD)
0.6-0.8-1.0-1.2-1.6 solid wire
0.8-1.0-1.2-1.6 aluminium wire
1.2-1.4-1.6-2.0-2.4 flux-core wire
1.5÷22 m/min.
yes
yes
yes
yes
no