Checking the welding
Working with the hand inductor
Alternatively it is also possible to carry out welds with the hand inductor
(available as an option). This may be appropriate on roof upstands, around
rooflights, on shed roofs etc.
The hand inductor is controlled via the main tool and automatically adopts all
functions and settings from it!
isoweld
®
3000
Fig. 2
isoweld
Backpack
®
Fig. 3
Please note that the underside of the inductor must be positioned
parallel to the top face of the plate!
If the correct parameters have been selected for the
welding and the recommended test weld has been
successful with positive results, and the instructions in
the operating instructions have been followed, no further
checks of the operation are necessary.
If you are not sure whether certain joints have already
been welded, SFS recommends using the suction pad
provided or a commercially available suction device to carry
out a test. Try to lift the roofing membrane at the point
in question. If that is possible, the joint is still open and
requires welding.
1. Unplug the tool.
2. Unplug the inductor from the main tool.
3. Plug the hand inductor into the main tool (see Fig. 2).
4. Plug in the tool.
5. Carry out calibration as described in the "Calibration"
section.
6. For further steps, see "Operation: welding" section.
remove
1. Remove the handle adaptor (see Fig. 3) and the inductor
becomes a hand-held tool.