Operation: welding
DANGER!
Danger of falling!
Careless working on the roof can lead to falls.
When working on a roof you must wear appropriate safety equipment.
Never use the tool backwards, but always in a forwards direction (see
sections on Hazards and Work position).
It is not permitted to use the isoweld
wear the isoweld
circumstances. Non-observance involves the risk of dealth or injury,
damage to the tool and damage to the processed material.
The induction welding tool and the magnets may have an effect on the
function of cardiac pacemakers and implanted defibrillators. It is possible
that cardiac pacemakers switch to test mode and cause discomfort. It
is possible that defibrillators cease to function. If you are fitted with any
such instruments, you must keep a minimum distance of 20 inches (50
cm) from the inductor (also hand inductor) and the magnets. You must
warn persons fitted with such instruments against coming too close to
the magnets and inductors.
N OTI CE
USE ONLY SFS MARKED PLATES
Welding with plates without an SFS
stamp may result in roof assembly failure.
Before installing the waterproof membrane, SFS recommends that the
position of the plates on top of the insulation be checked. Should the
height of any stress plate be incorrect, the height needs to be corrected.
underdriven
Before carrying out the welding, SFS recommends marking the position
of the stress plates on the top face of the waterproof membrane.
Backpack over a safety harness, under any
®
correct
Backpack as a safety harness or
®
overdriven
min. 2 mm
23