Additional setting options
By pressing the
and the unit of measure (mm/mil).
OK
1. Press the
2. Press the
L
3. Confirm the selection by pressing the
4. Press the
M
5. If you want to change these too, repeat steps 1 to 3 accordingly.
6. Press the Menu button in order to return to the standard view.
The parameters have now been set and stored.
The tool is now ready for operation. (status display
Test welding
SFS recommends that a test weld be carried out
after calibration and before starting installation. Po-
sition a stress plate on a level, heat-resistant base
and place a piece of the waterproof membrane to
be used on it. Carry out a test weld (see section on
welding operation). Allow the weld to cool down for
at least 10 minutes. Try to disengage the plate from
the waterproof membrane with the help of pliers.
If the membrane offers a lot of resistance or is destroyed in the process
(after tearing off the stress plate), the weld has been successful. Should
the welded waterproof membrane not have sufficient adhesion to the
stress plate, you need to check the settings (parameters) at the tool etc. For
technical assistance, please contact your service provider. You will find this at
1-800-DEKFAST (335-3278) or www.sfsintecusa.com (US) or
www.sfsintec.ca (CA)
22
button you can set the volume and tone of the signal sound
Menu
To set one of these parameters, proceed as
follows:
For example, the position display is on selection
of volume (*first line).
button. ≥ appears and flashes.
or
M
button until the required volume is reached.
button to move to the selection of tone or unit of measure.
button.
appears.
OK
M
lights up green).