EN
3.2.5. Operation in sequential mode with automatic
closing a er time delay
The gate is automatically closed a er a time-delay programmed during
installation.
A new command sent during this time-delay cancels automatic closing
and the gate remains open.
The subsequent command causes the gate to close.
3.2.6. Operation using the backup battery
If a backup battery is installed, the motorisation will work even during a
power outage.
Operation is then activated under the following conditions:
• Reduced and constant speed.
• The additional devices (photoelectric cells, orange light, wired code
keypad, etc.) do not operate.
Battery specifications:
• Battery life: 24 hrs; 3 operating cycles depending on the weight of
the gate.
• Recharging time: 48 hours
• Service life before replacement: Approximately 3 years.
3.3. Adding remote controls
3.3.1. Keygo io
This operation is used to copy the function of a button on a memorised
Keygo io remote control to a button on a new Keygo io remote control.
1)
A
3)
B
Remote control "A" = "source" remote control already memorised
Remote control "B" = "target" remote control to be memorised
For example, if the button on remote control A opens the gate fully, the
button on the new remote control B will also open the gate fully.
4
3.4. Emergency manual release
1) Insert the key into the lock.
2) Turn the key a quarter of a turn to the le .
3) Turn the release handle to the right.
3.5. Locking the motorisation
1) Turn the release handle to the le .
2) Move the gate manually until the drive mechanism locks.
2)
2s
3) Turn the key a quarter of a turn to the right.
4) Remove the key.
4)
4. MAINTENANCE
4.1. Checks
4.1.1. Safety devices (cells, safety edge)
Check for correct operation every 6 months.
4.1.2. Backup battery
For optimum battery life, it is recommended that the main power supply be
switched off and the motor operated using the battery for several cycles,
three times a year.
4.2. Replacing the battery
Attention
Do not forcibly push the gate. Hold the gate over its entire travel
during manual manoeuvres.
[1]
[2]
Attention
The motorisation must be locked before a new command.