During installation, the ANCHOR CABLE is looped around the
structure and closed using an EN 362-certified carabiner. The
ANCHOR CABLE can also be used as a single strand to extend an
anchor point, whereby a carabiner with a corresponding EN
362-certified load rating must be used. However, the cable is not a
lanyard and is not certified as such. The fall-arrest system or
lanyard is fastened to one of the eyelets on the cable or the O-ring
using the fixings provided for this purpose. If it is not possible to
anchor to these by means of eyelets constructed from thimbles on
the cable (through loops) or to the O-ring, the connecting carabiner
can be used as the anchor point. In this case, dynamic movements,
such as pulling the cable, must be avoided to prevent the connecting
carabiner from unscrewing.
2.5) ANCHOR CABLE JP-017-X=(length)
The ANCHOR CABLE has been type-tested in its various lengths in
accordance with EN 795/B for use by one person.
The maximum test load is: 12kN
Marking:
Articlename/
Artikelbezeichnung
ANCHOR CABLE 5mm
max.
Max. user/
Max. Nutzerzahl
Art-No.
Article No./
Artikelnummer
Serial-No. XXXXXX-XXX
Serial No./
Seriennummer
0123
Notified Body/
CE Kennzeichnung der
überwachenden Stelle
EAN Code
2.5.1) Installation:
In accordance with the maximum test load of the ANCHOR CABLE,
the structure to which the cable is attached must be able to support
a load of at least 9 kN.
In any case, it must be ensured that the cable is not attached
to any "open" structure (such as the end of a steel girder) from
which it could slip out under load.
JP-017-X
NEXT
INSPECTION
Internal code/
Interner Code
Im Mühlengrund 6-8
56566 Neuwied
Germany
+49 (0)2631/9680-0
www.skylotec.com
03/2017
EN 795/B:2012
Manufacturer incl. address/
Hersteller inkl. Anschrift
Space for inspection label/
Platz für Inspektionslabel
Refer to user manual/
Anleitung beachten
Date of manufacture/
Baujahr und Monat
Relevant standards /
relevante Normen