During installation, the HERCULES is looped around the structure
and closed using an EN 362-certified carabiner. The protective
jacket which is attached over the loop's cable must be positioned at
the support points.
The HERCULES loop can also be used as a single strand to extend
an anchor point, whereby a carabiner with a corresponding EN
362-certified load rating must be used. However, the loop is not a
lanyard and is not certified as such. The fall-arrest system or
lanyard is fastened to one of the two eyelets on the loop using the
fixings provided for this purpose. If it is not possible to anchor to
these by means of eyelets constructed from thimbles on the cable
ends (through loops), the connecting carabiner can be used as the
anchor point. In this case, dynamic movements, such as pulling the
loop, must be avoided to prevent the connecting carabiner from
unscrewing.
2.2) ANCHOR CABLE L-0002-X (X=length)
The ANCHOR CABLE has been type-tested in its various lengths in
accordance with EN 795/B for use by one person, and also tested
for use by three people in accordance with CEN/TS 16415.
The maximum test load is: 22.2kN
Marking:
Articlename/
Artikelbezeichnung
Article No./
Artikelnummer
Serial No./
Seriennummer
XXXXXX-XXX
Date of manufacture/
02/2018
Baujahr und Monat
Relevant standards
and CE marking of the
16415:2017-11
supervision/
relevante Normen und
CE Kennzeichnung der
überwachenden Stelle
2.2.1) Installation: In accordance with the maximum test load of the
ANCHOR CABLE, the structure to which the cable is attached must
be able to support a load of at least 9 kN.
In any case, it must be ensured that the cable is not attached
to any "open" structure (such as the end of a steel girder) from
which it could slip out under load.
6
X
Z359.18-2017 3.2.1
L-0664-X
Max. user/
Internal code/
Max. Nutzerzahl
Interner Code
Manufacturer incl. address/
Hersteller inkl. Anschrift
Space for inspection label/
Platz für Inspektionslabel
Refer to user manual/
Anleitung beachten
EAN Code