CODE
POSSIBLE
CAUSE
...............
POSSIBLE SOLUTION
24
Fuse blown, circuit breaker tripped
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker
with higher rating than that specified for your particular
branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
25
Tank Pressure exceeds pressure switch cut4n pressure
Motor will start automatically
when tank pressure drops
:
below cut-in pressure of pressure switch.
26
Pressure release valve on pressure switch has not
Set the On/Off switch to OFR If the valve does not open,
unloaded head pressure
replace switch. Contact a DEWALT factory service center or
a DEWALT authorized service center.