Changing The Battery; Charging The Battery - Rothenberger ROMAX Compact Instrucciones De Uso

Ocultar thumbs Ver también para ROMAX Compact:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26

Changing the battery

Insert battery until the catch clicks into place. (LED
flashes briefly = Contact made).
To remove press the catch and take out the
battery.
If the battery voltage is lower than necessary,
the LED flashes red. Charge the battery in the
charger.
EMERGENCY STOP Buttom
If there is any danger to personnel or the machine
during the pressing process, press the EMERGENCY
STOP button immediately and release the ON
switch. The valve will open and the piston will
return to its initial position.
LED
The LED can indicate the following:
Flashes red: Battery is flat. The current press
process will be ended automatically. The ON
button will then be disabled and a new cycle can
only be started once the battery has been charged.
Lights up red: After 10,000 press cycles the LED
lights up red after each moulding cycle to indicate
that the next inspection is due.
An internal counter keeps a record of the number
of pressing since leaving the factory.
To switch on
Press and hold the ON button until the moulding
cycle can be finished.
The motor cut out indicates the end of the
moulding cycle.
To insert the press jaw
Remove battery!
1
Open the bolt.
2
Insert the appropriate press jaw for the job in
hand.
3
Lock the bolt.
After changing the press jaw it is essential to
ensure that, once engaged, the crimping jaw
matches the profile being moulded and the
nominal width of the fitting being moulded. A
visual inspection must be carried out in order to
determine that the press jaw is fully closed at the
end of the press cycle.
To turn the press jaw
The press jaw can be turned through 270°
depending on the application.
12
A
Operation
Use only system-compatible press fittings and press
jaws designed for them. The nominal size of the
press jaw must be identical with the nominal size
of the press fitting.
When inserting the pipe / press fitting
system, there is a risk of crush injuries for
the fingers or other body parts near the
press jaw!
B1
1
Push the press fitting on to the pipe. Pull the
press jaw apart and insert the pipe with the
press fitting at right angles.
There must be no foreign bodies between the
press contour and the fitting. If you fail to
ensure this, the pressing process will not
B2
produce a perfect joint.
2
Press and hold the ON button until the
moulding cycle is finished.
The motor cut out indicates the end of the
moulding cycle.
3
Push the press jaw apart and take the machine
off the joint.
Do not start the machine while the piston retracts
or the emergency shutdown is pressed!
Battery/Charger
Mains connection:
B3
Connect only to single-phase a.c. current and only
to the system voltage indicated on the rating plate.
It is also possible to connect to sockets without an
earthing contact as the design conforms to safety
class II.
C

Charging the battery:

ATTENTION! Overvoltage destroys the
batteries and the charger. Observe
correct mains voltage.
The lithium-ion battery can be charged at every
charging level and charging can be interrupted at
any time without damaging the battery (no
memory effect).
1
Insert mains plug of the battery charger into a
mains power socket.
2
Connect the battery (1) to the battery charger
(2).
Charging control lamp yellow (3) lights up:
D
Battery is charged.
Charging control lamp yellow (3) and green
(4) flashes:
Battery is fully charged.
(For charging time, see Technical Data).
ENGLISH
E
F
Tabla de contenido
loading

Tabla de contenido