5. TECHNICAL DATA AND CHARACTERISTICS

5.1 Dimensions and connections

380
fig. 33 - Dimensions and connections
1 =
System delivery - Ø 3/4"
3 =
Gas inlet - Ø 3/4"
5 =
System return - Ø 3/4"

5.2 General view and main components

5
278
161
341
196
fig. 34 - General view
195
120
120
195
630
45
270
250
65
1
3
5
16
81
82
22
19
186
14
36
114
32
44 193
145
cod. 3541H790 - Rev. 00 - 12/2015

5.3 Plumbing circuit

278
196
193
154
44
10
fig. 35 - Plumbing circuit
Key fig. 34 and fig. 35
5
Sealed chamber
7
Gas inlet
10
System delivery
11
System return
14
Safety valve
16
Fan
19
Combustion chamber
22
Burner
32
Heating circulating pump
36
Automatic air vent
44
Gas valve
81
Ignition electrode
82
Detection electrode
114
Water pressure switch
145
Pressure gauge
154
Condensate outlet pipe
161
Condensing heat exchanger
186
Return sensor
193
Trap
196
Condensate tray
210
Hot water tank return
278
Double sensor (Safety + Heating)
341
Exchanger probe
16
161
186
114
36
210
32
14
7
11