CONCENTRIC FLUE PIPE INSTALLATION
Concentric flue pipe
Fit the concentric elbow pipe positioning it on the desired direction and insert on it the sealing gasket. Then
fit the appropriate diaphragm (see table below).
Fit the air intake and flue exhaust pipes, observing the distances indicated on the installation scheme. The
flue pipe should slope slightly outward.
CONCENTRIC FLUE PIPE
Ø100
Max. 3000
DOUBLE FLUE PIPE INSTALLATION
DOUBLE FLUE PIPE
ATTENTION: Use only air intake/ fumes evacuation kit produced by Lamborghini Caloreclima.
230
100
450
CONCENTRIC FLUE PIPE
Max.
lenght 1 mt
Diaphr.
Ø 80 mm
NOTE: Maximum length of CONCENTRIC FLUE PIPE 3 mt.
Installing an elbow to connect the boiler to the chimney will cause a
drop in pressure. The values set out in the table below indicate the
necessary modifications to the length of the linear pipes.
TYPE OF
INSTALLATION
CONCENTRIC
FLUE PIPE
SEPARATE
INTAKE/EXHAUST
Max. 3000
250
360
Over 1 mt.
max. 3 mt.
Diaphr. Ø 94 mm
(standard)
Maximum length of DOUBLE FLUE PIPE
(Intake + Exhaust) 16.5 mt.
ELBOW FITTED
FLUE ELBOW PIPE
DOUBLE FLUE PIPE
Max.
10 mt.
Diaphr.
Diaphr. Ø 94 mm
Ø 80 mm
ELBOW FITTED
AT 90°
1 mt
0,6 mt
45
Air
diaphragm
Over 10 mt.
max. 16,5 mt.
(standard)
AT 45°
0,5 mt
0,3 mt