CONNECTION TO THE CHIMNEY MOD. INOVA L24 MCS W TOP
The boiler is for combustion in a sealed chamber and does not require any special ventilation, it can be
located also in small rooms, lumber-rooms, laboratories. In addition, there are various possibilities for
combustion fumes evacuation and external air intake; basically the boiler is projected for two types of fumes
evacuation/air intake:
●
fumes evacuation/air intake concentric pipes system
●
fumes evacuation/air intake double pipe system
In this way it is possible, by using suitable mounting kits, to connect boiler to concentric flues, ventilating
flues, separate flues, etc.; some possible solutions are indicated in the following scheme.
FUMES EVACUATION/AIR INTAKE
1
Concentric flue pipe, from the roof C32
2
Concentric flue pipe, from the terrace C32
3
Double flue pipe from separate flues C42
Concentric flue pipe, connected to concentric flues C42
4
5
Concentric flue pipe, from an external wall C12
6
Double pipe, from the terrace C52
7
Double pipe, from single flue C82
For positioning and
for distances of
draught terminals
from windows,
doors, etc. see speci-
fications in force.