Maintenance And Warning Summary Table - Schneider Airsystems Air Master Serie Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
GB
It is important to indicate that the oil used is extremely significant. In fact, the use of oil different to that recommended (RotEnergy
Schraub)
Plus.) leads to the modification of maintenance intervals.
The passage to a different lubricant must be carried out ONLY AND EXCLUSIVELY on occasion of the first entire oil change and
it is EXTREMELY IMPORTANT NEVER TO MIX DIFFERENT TYPES OF OILS. Always use the same type of oil for successive
top-ups.
WASTE OIL IS HIGHLY POLLUTANT: dispose of it in compliance with legal provisions
Check oil level and top-up if necessary
Clean suction filter
Check transmission belt tension
Check blockage and cleaning of the radiator
Complete oil replacement
Oil filter replacement
Oil-separator filter replacement
Discharge condensation
Check minimum pressure valve
Replace flexible pipes
Replace transmission belt
Replace electric motor bearings
Replace screw unit sealing ring and bearings
Attention:
maintenance intervals are strongly influenced by environmental conditions and working conditions of the compressor.
16
16
16
16
16

MAINTENANCE AND WARNING SUMMARY TABLE

Type of maintenance
Oil used:
OETSYN-Schraub
OESYN-Schraub
RotEnergy Plus
Hours of service
100
500
1000
1000
4000
4000
4000
At least once a month
12000
12000
12000
12000
20000
(OETSYN-
Tabla de contenido
loading

Tabla de contenido