NOTE:
The information contained in this Manual is designed to assist you in the safe
maintenance of the Nailer.
Some illustrations in this Manual may show details or attachments that differ
from those on your own Nailer.
MAINTENANCE AND
INSPECTION
Read section titled "SAFETY" (pages 4 – 8).
Disconnect air hose and remove all
nails from Nailer when:
1) doing maintenance and inspection;
and
2) clearing a jam.
Never use gasoline or other highly
flammable liquides for cleaning.
1. Clearing a jam
Remove a jammed nail in the following
order:
1 DISCONNECT AIR HOSE.
2 Open the nail guide.
3 Insert a rod into the outlet.
Tap the rod with a hammer.
4 Remove the jammed nail with a
slotted screw driver.
MAINTENANCE
WARNING
Hammer
Rod
Outlet
1
Disconnect
air hose
Nail
5 Cut the deformed collated wire with
nippers.
Correct the deformation.
6 In case of frequent jam, contact a
Hitachi authorized service center.
2. Inspecting the feeders
1 DISCONNECT AIR HOSE.
2 Clean the knob sliding part.
Lubricate it with Hitachi pneumatic
tool lubricant.
Nail Guide
3 Open the nail guide and remove dust.
Lubricate the nose opening and
feeder shaft.
— 20 —
Slotted Screw Driver
Knob
1
Disconnect
air hose