8040_6000TDS_std_V1.3
10.1 REPLACEMENT OF THE 5μ CARTRIDGE FILTERS
1. Disconnect the electrical outlet from the equipment (Off RO)
2. Close the water inlet valve.
3. Unscrew the cap of the multi-cartridge filter, depending on models, first remove the
flange and in others unscrew the screws and remove the cover.
Multi-cartridge filter image in stainless steel and PVC respectively.
Subsequently unblock the piece (rod) that forces the cartridges to remain in their upright
position. It is possible that in this step some water spills, take precautions
4. Remove the filter to be replaced and drain the water from the compartment.
5. Rinse the compartment with water and detergent so that no dirt remains.
6. Check that the gasket and the thread are in good conditions. Replace if necessary.
7. Place the new filter in the compartment.
PP sediments filter.
8. Screw the filter holder compartment.
9. Open the water inlet valve.
10. Connect the electrical outlet of the equipment (star up RO).
66