Adjustment and calibration SEE ANNEX 1: CONDUCTIVITY CONTROLLER.
In case the equipment does not incorporate the RO3021 control panel, see the
corresponding ANNEXE 4 with the equipment manual delivered.
07 EQUIPMENT START-UP
This standard procedure may differ on your equipment, follow the steps given to you by
your installer.
1. Connect the equipment to the electrical system:
- Connect the power line first without hooking it into the main power supply
- Place a test buoy or a bridge where the buoy would be placed
- Check terminal block tightness
- Check that the motor protection switch, the starter and the contactor are correct
2. Connec the equipment to the hydraulic system:
- Make sure the water gets to the inlet connection.
- Connect the rejection and permeate outlets
3. Calibrate the conductivity-meter probe.
4. Adjust the low pressure switch (between 1.5 and 3 bar pressure to regulate the
pressure of the equipment inlet).
5. Start-up the equipment:
- Make sure that the electronic motor protection relay of the pump is switched off (to
work without the pump).
- Start the equipment the selector ON the electric panel (to check that the button works
perfectly).
- Check that the equipment starts with a wash (maneuver flushing) of the seconds
programmed according to model:
MODELS
OI2180
Recommended
120 sec
Flushing time
MODELS
OI2380
Recommended
120 sec
Flushing time
- Check that the equipment enters work mode (even though the pump does not start
because the electronic motor protection relay switch is disconnected).
6. Check the equipment looking for leaks in the installation.