06.2 OSMOTIZED WATER ACCUMULATION TANK FLOAT ELECTRIC CONTACTS (RO2097
OPTION)
The supplied osmosis equipment requires an electrical signal connected to the electrical
panel for the order to fill or stop the permeated water tank.
Technical features:
- 20 A resistive load. charge. 8 A engine load. Starter motor charge
- Cable diameter: 8.8 mm wire
- Temperature of use: min. +5°C - max. +60° C.
- 10 m maximum depth.
- Degree of protection: IP68. Protection degree
To set the counterweight follow the steps according to the type of counterweight
supplied:
Observations during handling of the float:
- Remember to disconnect the power supply before performing any operation involving
the float.
- The wire of the float is an integral part of it, so it must be replaced in case that any
damage, cut or fissure appears or is detected on it.
- Do not make splices on the float wire so that the immersion in water of the same can
cause short circuits and electric shocks due to the poor watertightness of the repair.
Connection of the float cable to the terminal board of the electrical panel of the equipment
according to the diagrams that are attached to this manual, so that it is in normally closed
contact (ON) while the tank is not full and open (OFF) when the tank is full up to the level
adjusted with the float.
Installation float for signal activation.
55