5.5 Ventilation:
n A steam ventilation hood is not absolutely stipulated for
the operation of the unit. If a hood is installed, the
following should be noted:
n VDI Guideline 2052 as well as the guidelines of the
local building commission for steam exhausts and
ventilation chimneys, respectively the relevant guidelines
and regulations in each country must be observed.
n Hood should protrude 300-500 mm over the front side
of the unit.
n Install the grease filters in the protruding area of the
hood.
n The grease filters should be removed and cleaned in a
dishwasher regularly. Note the manufacturer's
statements.
n An adequate amount of incoming air must be ensured
when operating the ventilation hood. Also see the table in
Chapter 6.
n Technical Data:
Model
Ventilation hood for electric units
Main power supply
Fuse protection
Water protection class
Fan capacity at ρ =1.2kg/m³
Fan capacity at ρ =1.2kg/m³
Fan capacity at ρ =1.2kg/m³
Material
5.6. Connection of a communication interface
n All Convotherm steamers are fitted with a RS232
communication interface. To connect a PC by means of
this RS232 interface cable Part-No. 5009315 is required.
Art.-Nr.: 7006300 / Ausgabe 06/2003
n When assembling the ventilation hood onto the unit,
make sure that the unit is secured against tipping,
especially with a stacking unit and when the unit is on a
stand with wheels.
n Always switch on the ventilation hood when the
combination oven steamer is operating. Otherwise
condensation can accumulate in the hood.
n If a ventilation hood is to be installed, we recommend
the original Convotherm Ventilation Hood Type 3408872
for the unit sizes CONVOTHERM 6.10 and
CONVOTHERM 10.10. A ventilation hood is available for
the unit size CONVOTHERM 10.20 upon request.
1 = On / Off switch
2 = Grease filters I and II
3 = Vent screen
4 = Outgoing air connection piece
5 = Specification plate
Ventilation hood type 3408872
CONVOTHERM 6.10 and 10.10
1/N/PE 50/60 Hz 230V
16 A
IPX5
1450 m³/h free blowing
1390 m³/h at ∆p = 8mmWS
1100 m³/h at ∆p = 16mmWS
STAINLES STEEL
n A separate communication module is required to
connect a Convotherm steamer to a network (RS485).
Please follow the installation instructions supplied with
the communication module.
Seite 22 / 71