B EL O W C O U N T E R
eSpring
FAUCET
®
IN S TA L L ATI O N
( 10 - 0 1 8 9 )
REVIEW ALL INSTRUCTIONS TO BE SURE YOU HAVE
ALL PARTS AND TOOLS PRIOR TO INSTALLATION.
eSpring Auxiliary Faucet Components (Fig. 18):
a. Spout
b. Spout cap
c. Body with red, green and blue tubes
d. Rubber washer
e. Metal washer
f. Wing nut
g. Supply Connector with flow controller
h. Tubing Removal Tool
NOTE: Supply Connector must be used for all installations.
1. a) Lay the RED and GREEN tubes on the top of the diagram, and lay the BLUE
tube on the bottom. Use a pen to mark them at the arrows (Fig. 19).
b) Use a ruler or lay the tube from the cold water supply on the top of the
diagram and mark a line at ¾" (18mm) or at the arrow (Fig. 19).
2. Press Faucet tap spout into the main body
and Screw spout cap onto faucet body top (2) Un-
screw to remove the wing nut and metal washer while
keeping the rubber washer against the faucet body
(Fig. 20).
3. Holding the rubber washer in place against the
faucet body, lower the eSpring Faucet stem and
tubes through the hole in the sink ledge or counter
. With an assistant holding the faucet in place,
reach up from below the counter and slide the
metal washer then the wing nut onto the threaded
faucet
. Position the faucet in the desired
orientation and tighten the metal washer and wing
nut to secure the faucet in place
NOTE: If the faucet remains loose, an additional
spacer may be required. Refer to Service Components
List, p. 11.
4
1035793_eng.indd 4
a.
b
c
d
e
f
h
g
Fig. 18
⁄
"
3
4
(
)
⁄
" (
)
Fig. 19
5
8
.
Fig. 20
(Fig. 21).
Fig. 21
4. Remove the Top Shroud from the Water
Purifier
. Remove the Electronic
Module
(Fig. 22).
5. Insert the GREEN and BLUE tubes at-
tached to the eSpring Auxiliary Faucet
into their proper locations on the
Bracket (Fig. 23).
NOTE: You will feel resistance before the
tubes are fully installed. Ensure the tube
is fully pushed in until it meets the mark
or the marks disappear as a check on
each of the tube connections in steps 5-6.
6. Connect the tube from the cold water
supply to the screen side of the Sup-
ply Connector
. Arrow in balloon
shows water flow direction
.
Insert the RED tube attached to the
Auxiliary Faucet into the opposite end
of the Supply Connector
(Fig. 24).
NOTE: You must use the Supply Connector
(Fig. 18, part c) between the valve at the
water supply and the eSpring Faucet.
7. Open the eSpring Faucet
. Open the water supply
shut-off valve to start water
flowing through the Water
Purifier
(Fig. 25).
NOTE: It will take a short time
for water to saturate the
Cartridge and flow from the
Diverter. Flush for a minimum
of 5 U.S. gallons (20 liters)
(approximately 5-15 minutes) to
remove air pockets and carbon
dust. If water is not clear, see
Troubleshotting, p. 8.
8. Turn off the eSpring Faucet and check for any signs of leakage at all tubing
connections
(Fig. 25). If there is leaking or bubbling, refer to Trouble-
shooting, p. 7.
NOTE: Purchase 10-1398 to use in installation to a refrigerator or other
secondary device.
9. Skip to COMPLETING THE INSTALLATION, p. 10.
Residents of Massachusetts, please adhere to the State of Massachusetts
Plumbing Codes. Use a licensed plumber for installation.
Fig. 22
Fig. 23
Fig. 24
Fig. 25
6/10/14 4:42 PM