Important Safeguards; Important Notes - Amway eSpring Manual Del Propietário

Ocultar thumbs Ver también para eSpring:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

IM P O R TA N T SA FE G UA R DS
WHEN USING AN ELECTRIC APPLIANCE, BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE
THE RISK OF FIRE, ELECTRIC SHOCK, AND/OR INJURY TO
PERSONS INCLUDING THE FOLLOWING:
1. READ ALL INSTRUCTIONS BEFORE USE. If you still have questions
concerning the installation or operation of your eSpring
contact Customer Service toll-free, p.13.
2. All wiring connections must comply with local electrical codes. Improper
electrical connection can result in a risk of electric shock. Check with
a qualified electrician if you are in doubt as to whether the product is
properly installed.
3. To protect against electric shock, do not place cord, power adapter, base
housing or Electronic Module in water or other liquids.
4. Supervision is required when any appliance is used by or near children.
5. To disconnect appliance from electrical power, remove power adapter from
electrical outlet.
6. Remove power adapter from electrical outlet before cleaning or performing
routine maintenance (i.e. replacing the cartridge).
7. Do not operate any appliance with a damaged electrical cord or power adapter
or after the appliance malfunctions or has been damaged in any manner.
8. Use only factory authorized replacement parts. Any defect or diminished
performance caused by the use of any unauthorized System parts or
accessories is not covered under the Limited Warranty, pp. 13-14.
9. Do not use outdoors.
10. The device is to be supplied through a residual current device outlet having a
rated residual operation current not exceeding 30 mA. The outlet should not be
located directly above a sink, or in an area where it could be affected by water.
11. Do not let power cord hang over the edge of table or counter, or touch hot
surfaces.
12. For residential and light commercial use only. Do not use this appliance for
other than the intended use.
13. WARNING: THE APPLIANCE MUST BE DRY BEFORE APPLYING ELECTRICAL
POWER AND BE DRY AND FREE OF LEAKS DURING OPERATION.
14. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
ATTEMPT TO OPEN THE ELECTRONIC MODULE. NO USER SERVICABLE
PARTS ARE INSIDE THE ELECTRONIC MODULE.
15. DANGER: Improper connection of the power adapter can result in a risk
of electric shock. Do not modify the power adapter. If it will not fit into the
outlet, have a proper outlet installed by a qualified electrician.
16. CAUTION: Regularly inspect product and plumbing fittings for water leaks,
as water leaks can cause property damage.
17. Anytime Electronic Module display has a red cup or red phone, there is no
UV treatment. Contact Customer Service, p. 13.
18. The eSpring Water Purifier must use the designated pressure regulator
and flow controller for line pressure installations.
19. The System has been certified for the reduction of radon from drinking
water at a loading rate of 15.2 liters (four gallons) per day. The
certification is not for other potential radon sources including air. The
system should not be used on drinking water containing radon levels in
excess of 4000 pCi/L.
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
If your immune system is weakened or compromised and for medical
reasons, you need water of exceptional purity, consult your healthcare
provider before using.
P L E A SE R EA D A N D S AV E TH ES E I NS T R UCT I O N S
1035793_eng.indd 1
®
Water Purifier,
Information can be accessed via the internet at www.espring.com or contact Customer Service:
In the United States, call 1-800-253-6500 M-F 8 AM – 12 AM and Sat. 8:30 AM – 5 PM.
In Canada, call 1-800-265-5470 weekdays M-F 8 AM – 12 AM and Sat. 8:30 AM – 5 PM.
IM P O R TA NT NO TE S
The eSpring Water Purifier is designed for use only with cold, bacteriologically
suitable (potable) water.
1. System tested and certified by NSF International and WQA against NSF/
ANSI Standards 42, 53, and 55 as verified and substantiated by test data.
See Performance Data Sheet for individual contaminants and reductions
performance.
2. This Class B system conforms to NSF/ANSI 55 and contains an ultraviolet lamp
that requires replacement at intervals in accordance with the manufacturer's
instructions. The device is designed for the supplemental bactericidal treat-
ment of disinfected public drinking water or other drinking water that has
been tested and deemed acceptable for human consumption by the state and
local health agency having jurisdiction. The system is only designed to reduce
normally occurring non-pathogenic or nuisance microorganisms. Class B
systems are not intended for treatment of contaminated water.
3. Installation of the Water Purifier must comply with Federal, Provincial,
State, Municipal and local laws and regulations.
4. During normal operation, if the Water Purifier has not been used for several
hours (e.g., overnight), run water through it for 60 seconds prior to use.
5. DO NOT use with warm or hot water, as this may damage the Water Purifier.
6. DO NOT install under full line pressure. Must be installed with the following:
• Above Counter Diverter
• Below Counter eSpring Faucet
• Below Counter NON-eSpring faucet or dispensing device must be
installed with Pressure Regulator Kit (CXV3645).
7. Except for lead and a few other compounds, the eSpring Water Purifier
is NOT designed to remove soluble inorganic substances such as iron,
calcium, magnesium, nitrates, arsenic or fluorides.
8. Plumber's thread sealing compounds should NOT be used with the Water
Purifier.
9. USE ONLY silicone or food grade lubricants with the Water Purifier O-rings.
When cleaning, use a mild liquid dishwashing detergent and water.
10. The Electronic Module p. 6 will let you know when it is time to replace the
Cartridge.
11. THE CARTRIDGE (MODEL NO. 10-0186) MUST BE REPLACED AT LEAST
ONCE A YEAR. In areas of very poor water quality, you may see a drop in
the flow rate, indicating that Cartridge replacement may be needed more
frequently. Even if water flow rate is not affected, the Cartridge must be
replaced as soon as a year has passed or when it has filtered 1320 U.S.
gallons (5000 L) of water, whichever comes first.
The UV lamp in the Cartridge contains mercury. Please
12.
dispose of according to local, state or federal laws.
REMEMBER: OPERATIONAL, MAINTENANCE AND REPLACEMENT REQUIREMENTS
ARE ESSENTIAL FOR THIS PRODUCT TO PERFORM AS REPRESENTED. IT IS
IMPORTANT THAT ONLY THOSE REPLACEMENT ELEMENTS THAT ARE IDENTIFIED
IN THIS MANUAL ARE USED WITH THIS PRODUCT. THE LIMITED WARRANTY
DOES NOT COVER ANY DEFECT OR DIMINISHED PERFORMANCE CAUSED BY
THE USE OF ANY PART OR ACCESSORY THAT IS NOT COMPATIBLE WITH THE
eSpring WATER PURIFIER.
Residents of Massachusetts, please adhere to the State of Massachusetts
Plumbing Codes. Use a licensed plumber for installation.