Technical Specifications - REMS Picus S1 Instrucciones De Servicio

Ocultar thumbs Ver también para Picus S1:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
eng
● Check the areas concerned for concealed supply lines with a suitable fi nder
before drilling. Drilling can damage or sever gas or water pipes, electric cables
or other objects. Damaged gas pipes can cause explosions. Damaged water
pipes and electric cables can damage property or cause electric shocks. If you
do damage a water pipe, make sure that no water gets into the motor.
● Make sure that no water gets into the drive unit motor during operation.
There is a risk of injury by electric shock if water should penetrate.
● Never use the electric diamond core drilling machines for overhead work.
There is a risk of injury by electric shock if water should penetrate.
● Cease operation immediately in case of leaks in the water supply and fi x
the leak. Do not exceed a water pressure of 4 bar. There is a risk of injury by
electric shock if water should penetrate the motor.
● Do not operate the power tool in an explosive environment. Fumes or liquids
can ignite or explode.
● Clean the air vents of your power tool regularly. The motor fan draws dust
into the housing and a heavy accumulation of metal dust can cause injury due
to electrical hazards.
● Wear personal safety equipment. Use full face protection, eye protection
or protective glasses depending on the application. Where appropriate,
wear a dust mask, ear defenders, protective gloves or a special apron which
keep away grinding and material particles and protect you against sharp
edges and wear non-slip shoes to avoid injury from slippery surfaces. The
eyes should be protected against fl ying foreign bodies which occur in different
applications. Dust masks and respirators must fi lter the dust produced in the
application. Prolonged exposure to loud noise can lead to loss of hearing.
● Use the brace (12) provided with the drill for hand-held drilling. Losing control
of the power tool can cause injuries.
● Always be prepared for blocking of the diamond core drilling crown. Never
use stage 1 for hand-held drilling with REMS Picus SR. There is a danger of
injury from the power tool being torn from the hand and spinning round as the
torque increases.
● Do not lock the safety inching switch (21) for hand-held drilling. There is a
danger of injury from the power tool being torn from the hand and spinning round
as the torque increases. The power tool can then only be brought to a standstill
by pulling out the mains plug.
● Never put down the power tool until the diamond core drilling crown has
come to a complete standstill. Rotating diamond core drilling crowns can make
contact with the surface on which you put down the tool, causing you to lose
control of the power tool.
● Keep the connecting lead away from rotating diamond core drilling crowns.
If you lose control over the tool, the connecting lead could be severed or caught
and your hand or arm could get into the rotating diamond core drilling crown.
● Protect the working areas; on both sides in case of through-bores. A drilling
core could fall out and injure persons and/or cause damage.
● Make sure that the building statics are not negatively infl uenced by the
core drilling. Consult the building supervisors or a static engineer to determine
and mark the core drilling.
● Check where the bore water fl ows to in case of hollow parts. Damages (e.g.
frost damage) could be caused.
● Only use the power tool for dry drilling in connection with a suitable safety
vacuum cleaner/dust extractor. When working with mineral building materials,
e.g. concrete, steel-reinforced concrete, all types of masonry, all types of screed,
natural stone, a high degree of mineral dust containing quartz is produced which
is harmful to the health. Inhalation of quartz fi ne dust is harmful to the health.
The Directive 89/391/EEC on the taking of measures to improve the safety and
health protection of employees at work obliges the employer to carry out an
appropriate risk assessment at the employees place of work, determine and
evaluate the potential dust load and defi ne necessary protective measures. The
German technical ruling for hazardous substances TRGS 559 "Mineral Dust"
defi nes in Appendix 1 that work with slitting and cutting machines must be clas-
sifi ed in exposure category 3 if the effectiveness of the extraction has not been
proven. In accordance with EN 60335-2-69 a penetration level of < 0.1 % is
prescribed for sucking health hazardous dusts with an exposure limit/work place
limit (AGW) of > 0.1 mg/m³. For dry drilling of mineral building materials at least
one safety vacuum cleaner/dust extractor or dust class M should therefore usually
be used in order to effectively extract the harmful dusts from machines. In addi-
tion, the respective national safety provisions, rules and regulations valid for the
application site must be considered and observed.
1 Technical specifi cations
Use for the intended purpose
WARNING
The REMS Picus electric diamond core drilling machines are intended for core drilling in mineral building materials such as concrete, steel-reinforced concrete, all types
of masonry, asphalt, all types of screed and natural stones using REMS universal diamond core drilling crowns, dry or with water feed, hand held or on a drill stand in
connection with a safety vacuum cleaner/dust extractor, e.g. REMS Pull M.
All other uses are not for the intended purpose and are therefore prohibited.
1.1 Scope of Supply
REMS Picus S1 Basic-Pack:
REMS Picus S1 Set 62:
REMS Picus S1 Set 62 Simplex 2:
REMS Picus S3 Basic-Pack:
18
Electric diamond core drilling machine, water supply device, brace, start drilling aid with Ø 8 mm drill, size 3 Allen key, size
32 single open-ended wrench, operating instructions, steel case.
REMS Picus S1 Basic-Pack, REMS Universal diamond core drilling crown Ø 62 mm.
REMS Picus S1 Basic-Pack, REMS Simplex 2, REMS Universal diamond core drilling crown Ø 62 mm.
Electric diamond core drilling machine, water supply device, brace, size 32 single open-ended wrench, operating
instructions, steel case.
● Do not aim liquid jet at the power tool, not even for cleaning. Penetration of
water into the power tool increases the risk of electric shock.
● Pull the plug out of the socket before making device settings or changing
accessories. Many accidents are caused by accidental starting of power tools.
● Do not use the power tool if it is damaged. There is a danger of accident.
● Never let the power tool operate unattended. Switch off the power tool, pull
out the mains plug and remove all hoses during longer work breaks. Elec-
trical devices can cause hazards which lead to material damage or injury when
left unattended.
● Children and persons who, due to their physical, sensory or mental abilities
or lack of experience and knowledge are unable to operate the power tool
safely may not use this power tool without supervision or instruction by a
responsible person. Otherwise there is a risk of injury due to false operation.
● Only allow trained persons to use the power tool. Apprentices may only use
the power tool when they are over 16, when this is necessary for their training
and when they are supervised by a trained operative.
● Check the power cable of the power tool and extension leads regularly for
damage. Have these renewed by qualifi ed experts or an authorised REMS
customer service workshop in case of damage.
● Only use approved and appropriately marked extension leads with a suffi -
cient cable cross-section. Use extension leads up to a length of 10 m with
cable cross-section 1.5 mm², from 10 – 30 m with cable cross-section 2.5 mm².
Safety instructions for drill stands
WARNING
● Pull the plug out of the socket before making device settings or changing
accessories. Many accidents are caused by accidental starting of power tools.
● Set up the stand correctly before mounting the power tool. Correct assembly
is important to prevent the risk of collapsing.
● Fix the power tool securely to the stand before use. Slipping of the power
tool on the stand can lead to loss of control.
● Fix the stand to a fi rm, level surface or wall. The power tool cannot be guided
evenly and safely if the stand can slip or shake (see 3.3.).
● Do not overload the stand or use it as a ladder or scaffold. Overloading or
standing on the stand can shift the centre of gravity of the stand upwards and
cause it to tip over.
Explanation of symbols
WARNING
Danger with a medium degree of risk which could result in
death or severe injury (irreversible) if not heeded.
CAUTION
CAUTION
Danger with a low degree of risk which could result in minor
injury (reversible) if not heeded.
NOTICE
Material damage, no safety note! No danger of injury.
Read the operating manual before starting
Use eye protection
Use a respirator
Use ear protection
Use hand protection
Power tool complies with protection class I
Environmentally friendly disposal
CE conformity mark
eng
Tabla de contenido
loading

Tabla de contenido