English
4
Intended use
The mobile dust extractor is suitable for the ab
sorption and suction of dust which is hazardous
to health with limit values corresponding to
dust
class
'H'
in
60335-2-69, including wood and paint dust.
The mobile dust extractor is suitable for the ab
sorption and suction of dust with carcinogenic
and pathogenic particles, as well as asbestos
dust.
The mobile dust extractor is designed to absorb
water.
The mobile dust extractor is, in accordance with
EN 60335-1 and EN 60335-2-69, suitable for in
creased demands for commercial use.
The user is liable for improper or non-in
tended use.
5
Machine features
The specified illustrations appear at the begin-
ning of the Operating Instructions.
[1-1]
Sealing plug
[1-2]
Intake opening
[1-3]
Module slot
[1-4]
Appliance socket
[1-5]
Electrical outlet module circuit
breaker
[1-6]
Hose store
[1-7]
Handle
[1-8]
SysDoc
[1-9]
Hose diameter setting
[1-10] Suction power adjuster
[1-11] Switch
[1-12] Warning sticker
[1-13] Locking clip
[4] EN 60335‑2‑69: dust class
16
FIS-CTH (3 x) (L, M, H
HF‑CT H
NF‑CT
accordance
with
)
[4]
[1-14] Dust container
[1-15] Lever
[1-16] Brake
EN
6
Operation
Unauthorised voltage or frequency!
Risk of accident
► The mains voltage and the frequency of the
power source must correspond with the
specifications on the machine's name
plate.
► In North America, only Festool machines
with the voltage specifications 120 V/60 Hz
may be used.
6.1
Initial operation
► Open the locking clips [2-2] and remove the
top section of the machine [2-1].
► Remove the accessories from the dust con
tainer [2-3] and the packaging!
► Affix the accompanying sticker in your na
tional language over the text field on the
warning sign [1-12].
► Insert the sealing plug [1-1] on the panel
(see Fig. [1a] ).
► Place a filter bag or safety filter bag in the
dirt trap in accordance with statutory re
quirements (see Chapter
► Replace the top section [2-1] and close the
locking clips [2-2].
► Attach the cable holder to the rear of the
mobile dust extractor (see Fig. [3]).
► Connect the suction hose to the machine.
6.2
Switch on/off
► Insert the plug into an earthed socket.
CTH 26 E
CTH 48 E
497541
497542
498995
498995
496169
496169
WARNING
7.7
,
7.8
).