[1-14] Automatic cleaning
[1-15] Hose diameter setting (only dust
class M)
[1-16] Closing slide (ComfortClean)
4 Technical data
Mobile dust extractors
Power consumption
Maximum appliance socket connected load
Max. suction capacity (air), turbine
Max. vacuum, turbine
Filter surface area
Suction hose
Length of the net cable
Sound pressure level as per EN 60704-2-1 / Uncertainty K
Protection category
Container capacity
Dimensions L x B x H
Weight
5 Intended use
Mobile dust extractors suitable for
CTL 26/36 E AC HD: Extracting dust up to 1
–
mg/m³ according to dust class 'L',
CTM 36 E AC HD: Extracting dust up to 0,1
–
mg/m³ according to dust class 'M' includ
ing wood and mineral quartziferous dust,
–
extracting water,
–
commercial use, for example in hotels,
schools, hospitals, factories, shops, offices
and rental businesses,
according to IEC/EN 60335-2-69.
The user is liable for improper or non-in
tended use.
14
The specified illustrations appear at the begin
ning of the Operating Instructions.
EU
CH, DK
CTL 26 E AC HD
CTL/M 36 E AC HD
CTL 26 E AC HD
CTL/M 36 E AC HD
CTL 26 E AC HD
CTL/M 36 E AC HD
6 Operation
WARNING
Unauthorised voltage or frequency!
Risk of accidents
► Observe the specifications on the ma
chine's name plate.
► Observe country-specific regulations.
6.1
Initial operation
► Open the locking clips [2-2] and remove the
top section of the machine [2-1].
► Remove the accessory parts from the dirt
trap [2-3] and the packaging!
► Insert the sealing plug [1-6] into the intake
opening [1-7] (for dust class M only).
► If necessary, attach the closing slide [1-16]
to the intake opening [3a], see Chapter
for more information.
English
350 ‑ 1200 W
2400 W
1100 W
234 m³/h (3900 l/min)
24000 Pa
6318 cm²
D 36/32 mm x 3.5 m‑AS
7,5 m
71 dB(A) / 3 dB
IP X4
26 l
36 l
673 x 365 x 455 mm
673 x 365 x 522 mm
14 kg
14,5 kg