Battery; Charging Procedure; Battery Handling; Environmental Protection - Gesipa AccuBird Instrucciones De Manejo

Ocultar thumbs Ver también para AccuBird:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
Use exclusively genuine plugs and cords and
genuine spare parts for repair.
Never use the charger in humid or wet environ-
ment, or close to inflammable substances or
gases: Explosion hazard!
Take the charger out of its package before use.
Insert the battery in the right way (pole+ to
pole+) into the charger bay. Insertion should
take place without noticeable effort.
Never try to charge non rechargeable batteries.
Store the charger in a dry closed room, out f
reach of children.
Never insert metallic parts into the charging
bay: Short circuit hazard.
When the charger is wall-mounted, make sure
that the inserted battery cannot fall down.

2.2.2. Battery

Caution:
Following safety rules must be followed
for adequate protection against electrical shock,
injuries or fire hazards:
Never try to charge a damaged battery.
Do not insert a dirty or wet battery into the
charger.
Never throw batteries into the waste, into fire
or into water.
Do not charge a battery when the environment
temperature is below 0°C.

2.3. Charging procedure

Charge only GESIPA batteries when the environ-
ment temperature is between 0°C and 40°C.
Take the charger out of its package and
connect to mains. Check the input voltage on
the type label before connecting.
Insert the battery in the right way (pole+ to
pole+) into the charger bay. Insertion should
take place without noticeable effort.
The charging operation starts automatically
when the battery is inserted into the charging
bay.
12
Function lights:
Steady green: Battery is charged,
preserv.charge in process
Blinking green: Charging
Steady red:
Charging temperature out of range
(battery too hot or too cold)
Blinking red:
Battery is defective
Typical charging cycles:
Type
Part Number
1,4 Ah NiCd
725 1017
1,7 Ah NiCd
725 1092
2,0 Ah NiCd
725 1095
3,2 Ah NiMH
725 1030
*charging cycles may vary according to the rest capacity and the
battery temperature.

2.4. Battery handling

Use only cold batteries to obtain optimum
charging.
The GESIPA batteries can be charged approx.
1.000 times and reaches its maximum capacity
only after several charging cycles.
Do not insert the battery into the charger after
each use, but wait until the battery is fully dis-
charged (tool cannot set the rivet).
Recharge the battery after a long period of
inactivity.
Battery autonomy becoming shorter despite of
proper recharging means that the battery must
be replaced.
Keep the battery in dry and warm rooms.
The optimum operating temperature range is
10°C to 50°C.

2.5. Environmental protection

If batteries have to be replaced,
the following instructionsshould be
followed:
Bring back discarded batteries to your GESIPA
agent or to GESIPA for recycling.
Never throw away discarded batteries into
waste, fire or water.
Charging cycle*
approx. 35 min
approx. 40 min
approx. 45 min
approx. 70 min
Tabla de contenido
loading

Tabla de contenido