DRYER VENTING
REQUIREMENTS
(in Australia and New Zealand, refer to AS/NZS
5601.1 = Gas installations)
if an Exhaust
Hood Cannot
be Used
The outside
end of main vent should
have a sweep
elbow
directed
downward.
t
305 mm rain,
(12")*
*Minimum
clearance
above any
accumulation
of snow,
ice, or
debris
such
as leaves
610 ram rain.
(24")*
Multiple
Dryer Venting
A main vent can be used for venting
a group of dryers. The main
vent should
be sized to remove 5663
I/min. (200 CFM) of air per
dryer. Large-capacity
lint screens
of proper
design
may be used in
main vent if checked
and cleaned
frequently.
The room where the
dryers are located
should
have make-up
air equal to or greater
than
CFM of all the dryers in the room.
Back-draft
Damper
Kit, Part No. 3391910,
is available
from your
distributor
and should
be installed
in the vent of each dryer to
keep exhausted
air from returning
into dryers and to keep exhaust
in balance
within main vent. Unobstructed
return air openings
are
required.
Each vent should
enter the main vent at an angle pointing
in the
direction
of the airflow. Vents entering
from the opposite
side
should
be staggered
to reduce the exhausted
air from interfering
with the other vents.
If main vent travels
vertically
through
the roof, rather than through
wall, install a 180 ° sweep
elbow on end of vent at least 610 mm
(2 ft.) above surface
of roof.
The opening
in wall or roof shall have a diameter
13 mm (1/2")
larger than vent diameter.
Vent should
be centered
in opening.
Do not install screening
over end of vent for best performance.
The maximum angle of each vent entering
the main vent should
be
no more than 30 ° .
Keep air openings
free of dry cleaning
fluid fumes. Fumes create
acids which, when drawn through
the dryer heating units, can
damage
dryers and items being dried.
A clean-out
cover should
be located
on the main vent for periodic
cleaning
of the vent system.
DRYER GAS SUPPLY REQUIREMENTS
(All piping is to be in accordance with AS/NZS
5601.1 = Gas Installations)
Make Gas Connection
Excessive Weight Hazard
Use two or more people to move and install washer/dryer.
Failure to do so can result in back or other injury.
1. Remove red cap from gas pipe.
2. Connect
gas supply to dryer. If the flexible gas hose has
10 mm (3/8")
BSP thread, use the supplied
conversion
thread
adapter.
Use pipe-joint
compound
resistant
to the action of L.R
gas for gas connections.
If necessary
for service,
open the toe panel. Use a putty knife
to press on the 2 toe panel locks located
at the top of the toe
panel. Pull downward
on the toe panel to open. Toe panel is
hinged at the bottom.
3. Open the shut-off
valve in the gas supply
line.
4. Test all connections
by brushing
on an approved
noncorrosive
leak-detection
solution.
Bubbles
will show a leak. Correct
any
leaks found.
17