9 Cleaning of the Unit
GB
The lens should be cleaned at regular intervals,
depending on impurities caused by dirt, smoke or other
particles. Only this will ensure that the light is radiated
at maximum brightness. For cleaning, disconnect
the mains plug from the socket. Only use a soft,
clean cloth and a glass cleaner. Then wipe the lens dry.
For cleaning the other parts of the housing, only use
a soft, clean cloth. Never use any fluid; it may leak into
the unit and cause damage.
10 Specifications
Power supply: . . . . . . . . 230 V~ / 50 Hz
Power consumption: . . . 50 VA
Light source: . . . . . . . . . 1 super bright white LED,
Ambient temperature: . . 0 – 40 °C
Dimensions. . . . . . . . . . 195 × 180 × 210 mm
Weight: . . . . . . . . . . . . . 3 kg
Subject to technical modification.
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
14
20 W
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
10.1 DMX channels
DMX value Function
Channel 1: colour
0 – 14
white
15 – 28
light green
29 – 42
yellow
43 – 56
purple
57 – 70
orange
71 – 84
light blue
85 – 98
dark green
99 – 112
warm yellow
113 – 127
dark blue
constant change of colour:
slow → fast
128 – 255
Channel 2: dimmer
dark → bright
0 – 255
Channel 3: stroboscope
0 – 7
light beam deactivated
8 – 15
light beam constantly activated
stroboscope: slow → fast
16 – 131
132 – 139
light beam constantly activated
The light beam will gradually become
brighter and will be deactivated after
reaching its maximum brightness*.
execution speed: slow → fast
140 – 181
182 – 189
light beam constantly activated
The light beam will gradually become
darker and will then switch back to bright*.
execution speed: slow → fast
190 – 231
232 – 239
light beam constantly activated
240 – 247
stroboscope with random flash sequence
248 – 255
light beam constantly activated
*depending on the adjustment of channel 2 (dimmer)