Ducting Information; For Future Reference - JENN-AIR 8113P755-60 Manual Del Usario

Idiomas disponibles

Idiomas disponibles

important Safety Notice
and Warning
The California Safe Drinking Water and Toxic
Enforcement
Act of 1986 (Proposition
65) requires the
Governor of California to publish a list of substances
known to the State of California to cause cancer or
reproductive
harm, and requires businesses to warn
customers of potential exposures to such substances.
Users of this appliance
are hereby warned that when
the oven is engaged in the self-clean
cycle, there may
be some low-level exposure to some of the listed
substances, including
carbon monoxide. Exposure to
these substances
can be minimized
by properly venting
the oven to the outdoors by opening the windows
and/
or door in the room where the appliance
is located
during the self-clean
cycle.
IMPORTANT
NOTICE REGARDING
PET BIRDS:
Never keep pet birds in the kitchen or in rooms where
the fumes from the kitchen could reach. Birds have a
very sensitive respiratory
system. Fumes released during
an oven self-cleaning
cycle may be harmful or fatal to
birds. Fumes released due to overheated
cooking oil, fat,
margarine
and overheated
non-stick
cookware
may be
equally harmful.
Save These instructions
for Future Reference
DUCTING
INFORMATION
Jenn-Air's ventilation
system is designed to capture both
cooking fumes and smoke from the cooktop surface. If
the system does not, here are some ducting installation
situations to check:
* 6" diameter round or 3 W' x 10" rectangular
ducting
should be used for duct lengths ] 0'-60'.
Important:
5" diameter round ducting may be used if
the duct length is ] 0' or less.
, No more than three 90 ° elbows should be used.
Distance between elbows should be at least 18".
, Recommended
Jenn-Air wall cap MUSTbe
used.
Make sure damper moves freely when ventilation
system is operating.
, There should be a minimum
clearance of 6" for
cooktop installed near a side wall.
If there is not an obvious improper
installation, there
may be a concealed problem such as a pinched joint,
obstruction
in the pipe, etc. Installation
is
the responsibility
of the installer and
questions should be addressed first by the
installer. The installer should very carefully
check the ducting installation
instructions.
, Use the Flow Tester Card provided with
your appliance to check the air flow.
FLOW
TESTER
t
4