Setting the Input and Output Ports

19.1

Input allocation for Port IN and the optional port 1 for the wind speed channel m/s

Use the four system keys
option, digital input 1 can be used to connect an anemometer or as another configurable gate input
like all other inputs. The input voltage range for digital inputs is between min. -5V and 30V DC
(Low=5V..5V, High= 11V..30V). Two actions can be stored for each input. The first of these actions is
started as soon as the input switches from Low to High status
started once the status changes from High to Low
message texts for the LCD display can be saved. The inputs can be configured by means of the
DEPENCE software. The sub-menu item
The following activities can be configured with the DEPENCE software
Activity:
StartShow
StopShow
SetFader
StopAll
Please see also chapter 12.
19.2

Output allocation Port Out

Use the four system keys
purposes, the digital outputs can be set by means of the
channels. The manual setting of the
software. A maximum of 1 ampere output at 24V DC can be applied to each output. The DEPENCE
software can be used to program the outputs within one show. The sub-menu item
be used to display the allocation of the outputs. Please read also chapter 13.
If the unit is restarted the previously active outputs are no longer active.
19.3

Allocation of output channel to DMX channel

Use the four system keys
to the sub-level menu item
desired output to a DMX channel, if necessary. Example:
Do not use the unit to control safety-relevant assembly components.
to get from the main level to the sub-menu item
3.Port IN
. can be used to display the allocation of the inputs.
Description:
Starts a WDS-file. If the scheduler has already started a shoe, it will be
discontinued. Furthermore, the scheduler will restart an 'unending'
show.
An ongoing show stops. All DMX-values are set to 0. The status of the
digital outputs remain unchanged.
A fader (grandmaster or submaster) is set to a defined value.
An ongoing show stops. All DMX-values are set to 0. All digital outputs
are set OFF. The scheduler is stopped.
to get from the main level to sub-menu item
Toggle Out
function is given priority over access by the DEPENCE
to get from the main level to the sub-menu item
Digital Outputs
. Use the function
(CMD IN
Raise). The second action is
(CMD IN
Release). In addition to the actions,
4.Port Out
Toggle Out
functions of the respective output
8.Setup
DO 1...8 Patch
DO 1 Patch
,U128.A001.
3.Port IN
. As an
:
. For testing
3.Port Out
. can
. Then proceed
to allocate the