3

TECHNICAL DATA

Mains voltage
Primary current
I
MIG/MAG
max
I
TIG
max
I
MMA
max
No-load power in energy-saving mode
6.5 min. after welding
Setting range
MIG/MAG
TIG
MMA
Permissible load at MIG/MAG
60 % duty cycle
100% duty cycle
Permissible load at TIG
60 % duty cycle
100% duty cycle
Permissible load at MMA
60 % duty cycle
100% duty cycle
Power factor at maximum current
MIG/MAG
TIG
MMA
Efficiency at maximum current
MIG/MAG
TIG
MMA
Electrode types
Open-circuit voltage without VRD function
VRD function activated
Operating temperature
Transportation temperature
Constant sound pressure when idling
Dimensions lxwxh
Weight
Insulation class
Enclosure class
Application class
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or cut at
a certain load without overloading. The duty cycle is valid for 40°C.
bu21e
Warrior 400i CC/CV
380-460V $10%,
3 50/60Hz
27A
23A
29A
30W
16A/15V - 400A/34V
5A/10V - 400A/26V
16A/20V - 400A/36V
400A/34V
300A/39V
400A/26V
300A/22V
400A/36V
300A/32V
0.84
0.75
0.82
91%
88%
91%
Basic
Rutile
Cellulosic
71V DC
< 35V
-10 to +40° C
-20 to +55° C
<70db (A)
712 x 325 x 470mm
52.5kg
H
IP 23
- 38 -
Warrior 500i CC/CV
380-460V $10%,
3 50/60Hz
37A
30A
38A
30W
16A/15V - 500A/39V
5A/10V - 500A/30V
16A/20V - 500A/40V
500A/39V
400A/34V
500A/30V
400A/26V
500A/40V
400A/36V
0.88
0.85
0.88
90%
87%
91%
Basic
Rutile
Cellulosic
84V DC
< 35V
-10 to +40° C
-20 to +55° C
<70db (A)
712 x 325 x 470mm
52.5kg
H
IP 23
© ESAB AB 2013