Roland XP-30 Manual Del Usuario página 185

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Effect 1 (Reverb Send Level) (Controller number 91)
status
2nd byte
BnH
5BH
n=MIDI channel number:
0H - FH (ch.1 - ch.16)
vv=Reverb Send Level:
00H - 7FH (0 - 127)
* Not received in Patch mode.
Effect 3 (Chorus Send Level) (Controller number 93)
status
2nd byte
BnH
5DH
n=MIDI channel number:
0H - FH (ch.1 - ch.16)
vv=Chorus Send Level:
00H - 7FH (0 - 127)
* Not received in Patch mode.
RPN MSB/LSB (Controller number 100, 101)
status
2nd byte
BnH
65H
BnH
64H
n=MIDI channel number:
0H - FH (ch.1 - ch.16)
mm=MSB of the parameter number specified by RPN
ll=LSB of the parameter number specified by RPN
<<< RPN >>>
Control Changes include RPN (Registered Parameter Numbers), which are extended
parameters whose function is defined in the MIDI specification.
When using RPNs, first the RPN (Controller numbers 100 and 101; they can be sent in any
order) is transmitted to specify the parameter you wish to control. Then, Data Entry
messages (Controller numbers 6 and 38) are used to set the value of the specified parameter.
Once a RPN parameter has been specified, all further Data Entry messages on that channel
are considered to apply to that specified parameter. In order to prevent accidents, when the
desired setting has been made for the parameter, it is recommended that RPN be set to Null.
This device receives the following RPNs.
RPN
Data entry
MSB LSB
MSB LSB
00H 00H
mmH -
00H 01H
mmH llH
00H 02H
mmH -
7FH 7FH
- -
3rd byte
vvH
3rd byte
vvH
3rd byte
mmH
llH
Notes
Pitch Bend Sensitivity
mm : 00H - 0CH (0 - 12 semitones)
ll : ignored (processed as 00H)
Up to 1 octave can be specified in semitone steps.
*The Bend Range parameter (PATCH/
CONTROL/KEY MODE & BENDER) will
also be changed.
*Not received by the Rhythm Part (Part 10).
Master Fine Tuning
mm, ll : 20 00H - 40 00H - 60 00H
( -8192 x 50 / 8192 - 0 - +8192 x 50 / 8192 cent )
*In Patch mode, the Master parameter
(SYSTEM/TUNE/TUNE) will change.
*In Performance mode, the Fine parameter
(PERFORM/PART/SETTING) of each Part
will change. When received on the Control
channel, the Master parameter (SYSTEM/
TUNE/TUNE) will change.
Master Coarse Tuning
mm : 10H - 40H - 70H (-48 - 0 - +48 semitones)
ll : ignored (processed as 00H)
*Not received in Patch mode.
*In Performance mode, the Coarse parameter
(PERFORM/PART/SETTING) of each Part
will change.
RPN null
RPN and NRPN will be set as Òunspecified.Ó
Once this setting has been made, subsequent
Data Entry messages will be ignored. (It is not
necessary to transmit Data Entry for RPN Null
settings.
Parameter values that were previously set will
not change.
mm, ll: ignored
Program Change
status
2nd byte
CnH
ppH
n=MIDI channel number:
0H - FH (ch.1 - ch.16)
pp=Program number:
00H - 7FH (prog.1 - prog.128)
* Not received when the Program Change parameter (SYSTEM/MIDI/RECEIVE MIDI) is
OFF.
* When received on the Control channel, the Performance will change.
* Not received in Performance mode when the Rx parameter (PERFORM/MIDI/MIDI) is
OFF.
Channel Aftertouch
status
2nd byte
DnH
vvH
n=MIDI channel number:
0H - FH (ch.1 - ch.16)
vv=Channel Aftertouch:
00H - 7FH (0 - 127)
* Not received in Performance mode when the Rx parameter (PERFORM/MIDI/MIDI) is
OFF.
Pitch Bend Change
status
2nd byte
EnH
llH
n=MIDI channel number:
0H - FH (ch.1 - ch.16)
mm,ll=Pitch Bend value:
00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)
* Not received in Performance mode when the Rx parameter (PERFORM/MIDI/MIDI) is
OFF.
Channel Mode Messages
All Sound Off (Controller number 120)
status
2nd byte
BnH
78H
n=MIDI channel:
0H - FH (ch.1 - ch.16)
* When this message is received, all notes currently sounding on the corresponding
channel will be turned off.
* Not received in Performance mode when the Rx parameter (PERFORM/MIDI/MIDI) is
OFF.
Reset All Controllers (Controller number 121)
status
2nd byte
BnH
79H
n=MIDI channel number:
0H - FH (ch.1 - ch.16)
* Not received in Performance mode when the Rx parameter (PERFORM/MIDI/MIDI) is
OFF.
* When this message is received, the following controllers will be set to their reset values.
Controller
Pitch Bend Change
Polyphonic Key Pressure
Channel Pressure
Modulation
Breath type
Expression
Hold 1
Sostenuto
Soft
Hold 2
RPN
NRPN
System General purpose controller 10
System General purpose controller 20
Aplicación MIDI
3rd byte
mmH
3rd byte
00H
3rd byte
00H
Reset value
[+-]0 (center)
0 (off)
0 (off)
0 (off)
0 (minimum)
127 (maximum)
However the controller will be at minimum.
0 (off)
0 (off)
0 (off)
0 (off)
Unset. Previously set data will not change.
Unset. Previously set data will not change.
(minimum)
(minimum)
185
Tabla de contenido
loading

Tabla de contenido