5. Setting the treatment values
Warning!
m
Patient hazard –
Before therapy, a test run consisting of
several exercise cycles must be com-
pleted without the patient. Then repeat
the test run with the patient and check
that the movement does not cause any
pain.
Note!
See also 2.2 and 2.3 as well as page VIII !
5.1 General information
on programming
ARTROMOT®-K1
1. You activate the programming mode by
briefly pressing the MENU key on the
programming unit.
2. The various treatment parameters and
functions are allocated to three (stand-
ard model) or five (Comfort model)
programming levels (four per level).
To be able to program a parameter you
will have to access the corresponding
programming level. This is also done
with the MENU key. With each key press
you advance one level. The code M1, M2,
etc. that appears in the middle of the
display indicates the programming level.
3. You activate the treatment parameters
and functions with the four parameter
keys below the display. The symbols
above the four parameter keys indicate
the assigned parameters and functions.
This is what happens when you press
one of the parameter keys to select a
parameter:
− The corresponding symbol appears on
the display in a larger format.
− The set value is displayed.
− The symbol above the parameter key
appears in reverse video.
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 51
4. With the +/- keys (plus/minus) you
change the displayed value. When you
press and hold the key, the value will
change at a higher rate.
Some of the (special) functions will only
be enabled and disabled. This is done by
pressing the corresponding parameter
key or with the +/- keys. Activated
parameters are identified with a check
mark in the circle next to the symbol.
5. Having programmed all parameters,
press the STOP key to save the values.
6. Then press the START key to start
therapy.
Note!
− Refer to sections 5.3 and 5.5 for a
description of the parameters.
− To view the set parameter values,
press the corresponding parameter
key. However, this is only possible
when you press the STOP key first.
− To prevent accidental changes of the
parameter settings, you can lock the
keys. To do so, simultaneously press
keys + and – for approx. 3 seconds.
Press both keys again for approx.
3 seconds to unlock.
− Selecting the "New Patient" function
will automatically delete the data on
the patient chip card. When you have
finished programming the unit and
press the STOP key, the settings will
automatically also be saved to the
patient chip card.
− Emergency stop function:
ARTROMOT®-K1 will stop immedi-
ately, when any of the keys is pressed
during therapy. Patient treatment
can be resumed by pressing the
START key. The device will automati-
cally change the direction.
51