Delay (shut off)
If the blower is off when the DELAY button is pressed, the
blower will turn on to the HIGH speed setting for 10
minutes. At the end of the cycle the blower will turn off.
If the blower is on when the DELAY button is pressed, the
blower runs for 10 minutes at the current speed then turns
off.
During the 10 minute timed period, the LED above the
DELAY button is illuminated.
To interrupt a timed period, press fan speed or OFF button.
Lights
This button controls the halogen lighting. The first press
turns the lights on. A second press dims the lights. A third
press turns the lights off.
1 — ON
2 — DIM
3 — OFF
Heat Sensor
(custom insert control panel only)
Heat sensor feature is disabled if a remote control is
installed.
Over-temperature Condition
The high temperature sensor protects the hood from high
temperatures which may damage components. The control
is set to activate at 161°F (72°C) and reset at 140°F
(60°C). When activated, the blower will turn on low and the
corresponding LED will blink, indicating an over-
temperature condition.
While the high temperature sensor is activated, the blower
speed can be changed or turned off. If the blower is turned
off, the corresponding LED will blink. Light controls will
remain operational. When the control sensor reaches
140°F (60°C), a reset will occur. During reset, the control
will revert back to the operational state prior to the high
temperature condition.
High Temperature Fault Condition
The circuit is equipped with an alarm indicating that the
heat sensor protection is not working due to a damaged
sensor. In the case of this extreme condition, the three fan
speed indicator LEDs will start blinking. All the controls will
be operational except for the speed indicators.