Malfunction
Damaged fastener head
The nail doesn't penetrate
deeply enough
The fastener doesn't hold in
the base material
Fastener breakage
(shear breakage)
Fastener breakage
(with deformation)
The head of the nail punches
through the material fastened
38
English
Possible cause
Too much driving energy.
The wrong piston has been fitted.
The piston is damaged.
Driving energy too low
The application limits have been
exceeded (very hard material).
The system is unsuitable.
Thin supporting steel (4­5 mm)
Driving energy too low
The application limits have been
exceeded (very hard material).
Driving energy too low
The application limits have been
exceeded (very hard material).
Too much driving energy.
Too much driving energy
Action to be taken
▶ Turn the selector ring for driving
energy to reduce driving energy.
▶ Make sure that the correct
piston / fastener combination is
used.
▶ Change the piston.
▶ Turn the selector ring for driving
energy to increase driving
energy.
▶ Use an extra-strong cartridge.
▶ Use a nail with a higher
application limit.
▶ Use a more powerful system ,
e.g. DX 76 (PTR).
▶ Use a different energy setting.
▶ Use a nail suitable for thin
supporting steel.
▶ Turn the selector ring for driving
energy to increase driving
energy.
▶ Use an extra-strong cartridge.
▶ Use a more powerful system,
e.g. DX 76 (PTR), with corre-
sponding suitable fasteners.
▶ Turn the selector ring for driving
energy to increase driving
energy.
▶ Use an extra-strong cartridge.
▶ Use a more powerful system,
e.g. DX 76 (PTR), with corre-
sponding suitable fasteners.
▶ Turn the selector ring for driving
energy to reduce driving energy.
▶ Turn the selector ring to reduce
driving energy.
▶ Use a less powerful cartridge
(titanium-gray).