3.3 CONTROL AND SAFETY DEVICES
If the appliance is not used for a long time or if it does not work or works irregularly, the gas stopcock upstream of the
appliance must be shut off.
All the parts of the appliance that are subject to wear can easily be accessed from the front of the appliance by opening
the door or after removing the front.
All the couplings use a dado and bicono, so great care must be taken in handling these components. If the part is
damaged during dismantling or reassembly it must be replaced with a new one.
If the oil exceeds the set temperature the safety thermostat breaks the contact with the thermocouple. To restart the
appliance, open the door and press the red push-button.
Warning. As the safety thermostat may have been triggered by a faulty gas valve or thermostat, any faulty parts must be
replaced by an authorized technician before the appliance is started up again.
TECHNICAL SPECIFICATIONS TABLE FOR CATEGORY II2H3+ GAS FRYERS
MOD.
RATED
OUTPUT
Kw
P.C.I.
7FRG‐17R
16,5
8FRG‐17R
16,5
7FRG‐34R
33
8FRG‐34R
33
8FRG‐22R
21
8FRG‐44R
42
THE
MANUFACTURER
INCORRECTINTERVENTIONS, TAMPERING WITH THE APPLIANCE, MISUSE, POOR MAINTENANCE,
NONCOMPLIANCEWITH CURRENT REGULATIONS AND INEXPERT USE.
THE MANUFACTURER RESERVES THE RIGHT TO WITHOUT NOTICE MODIFY THE FEATURES OF
THEAPPLIANCES DESCRIBED IN THIS MANUAL.
TANK
CAPACITY
NOZZLES
G30
G31
N° X Lt
1 x 17
120K
1 x 17
120K
2 x 17
120K
2 x 17
120K
1 x 22
140K
2 x 22
140K
ACCEPTS
NO
PRESSURE IN mbar
G30/G31 = 28/37
G20 = 20
LIGHT
G20
G30
G31
N°
180L
20
180L
20
180L
20
180L
20
200L
20
200L
20
RESPONSIBILITY
Pag. 19
AIR
G20
G30
G31
N°
mm
35
OPEN
35
OPEN
35
OPEN
35
OPEN
35
OPEN
35
OPEN
FOR
HARM
CAUSED
G20
mm
18
18
18
18
OPEN
OPEN
BY