Technical Features; Pellet Features - klover PELLET FIRE PLACE 18 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Technical features

Nominal heat output
Reduced heat input
Nominal heat input yield for heating water
Reduced heat input yield for heating water
Nominal power given-up to the environment due to radiation
Reduced power given-up to the environment due to radiation
Nominal heat input efficiency
Reduced heat input efficiency
Nominal capacity
Nominal voltage
Nominal frequency
Expansion vessel lt/preloading bar
Maximum working pressure/recommended
CO at 13% oxygen at nominal heat input
CO at 13% oxygen at reduced heat input
Minimum chimney effect at nominal heat input
Minimum chimney effect at reduced heat input
Combustion gas flow at nominal heat input
Combustion gas flow at reduced heat input
Exhaust gas temperature at nominal heat power
Exhaust gas temperature at reduced heat input
Pellet tank capacity
Pellet min – max hourly consumption
System load hydraulic connections
FLOW/RETURN heating hydraulic connections
Boiler body capacity
Width
Height
Depth
Minimum safety distance from flammable materials
Weight
* power absorbed only during the ignition phase (with a maximum duration of 10 minutes per cycle).
The data reported above is approximate and not binding. The manufacturer reserves the faculty to make any modifications to the product in order to
improve its performance.
The given heat power can change according to the pellet used.

Pellet features

The insert has been tested with all types of pellets present on the market. The pellets used must have the following features:
Diameter 6 mm;
Maximum length 35 mm;
Maximum humidity content 8 – 9 %;
100% wood. Total absence of additives.
1.1 % maximum ash residue
For good insert efficiency, we recommend the use of top quality pellets. Pellets must be poured into the tank using a shovel and not directly from
the bag.
In order to recognise pellet of quality it is necessary that:
It is manufactured with constant diameter cylinders and it has a smooth and glossy surface;
There is not a lot of sawdust inside the packaging;
If the pellet is poured into a container of water it will tend to sink if it is a quality pellet, while if it is not, it will tend to float;
The conditions of the quality certification and in particular the compliance with international Standards such as EN 14961-2 Wood pellet class A1-A2
(maximum moisture level of 10%), should be indicated on the packaging;
Packages are intact since pellets tend to absorb humidity. Humidity not only reduces the calorific value and increases exhaust gas, but it also swells
the product which could create problems in the insert.
International Standards must be respected for the manufacturing of pellets as in France, Austria, Germany and recently some countries from Eastern,
also must comply with the EN14961-2, DIN 51731 and the O-NORM M7135 Standards in the production phase. These Standards establish the minimum
values in order to check pellet quality. In Italy there is no official Standard, but it is recommended to use pellets that respect the previously-mentioned
Standards.
The use of poor pellets or pellets made of any other material can lead to damage of the insert functions and can also make the warranty null
and void and make the manufacturer exempt from all responsibility.
In order to guarantee combustion without problems the pellets must be kept in a dry place.
6
kW (Kcal/h)
14.7 (12,600)
kW (Kcal/h)
5.6 (4,800)
kW (Kcal/h)
12.6 (10,800)
kW (Kcal/h)
4.0 (3,400)
kW (Kcal/h)
2.2 (1,900)
kW (Kcal/h)
1.6 (1,400)
%
91.0
%
94.3
Watt
300*
V
220
Hz
50
6 / 1
bar
2.5 / 1.5
%
0.02
%
0.05
Pa
12.4
Pa
11.1
g/s
10.9
g/s
5.4
°C
128.6
°C
65.6
Kg
25
0.7 – 3.4
Kg/h
1/2"M
Ø
3/4"M / 3/4"M
Ø
litres
16
mm
758
mm
686
mm
675
mm
200
Kg
180

Hide quick links:

Tabla de contenido
loading

Tabla de contenido