poolstar Poolican Manual De Instalación Y De Uso página 123

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
USING THE CONTROL PANEL
4 /
Covered mode
Covering pools for prolonged periods of time may result in over-chlorination.
When the pool is covered, the application allows you to adapt the treatment time: to do this, activate
the cover button; Poolican will then reduce its treatment time. Remember to deactivate the cover
button when you uncover your pool.
If your pool is indoors, then the water treatment time
levels checked regularly.
5 /
Setting the desired temperature
The POOLICAN heat pump can be used in 3 different modes to better suit your needs:
HEATING (Full Inverter) :
This mode heats your pool water to between 15 and 40°C; by default the target temperature is 28°C .
N . B .: when starting the heating process, it may take up to 6 days to reach the desired temperature .
Be careful not to exceed the maximum temperature recommended by the manufacturer for your pool
liner (seek advice from a pool maintenance technician) .
COOLING (Full Inverter):
This mode cools your pool water to between 3 and 30°C; by default the target temperature is 28°C.
This mode can ensure that you do not exceed the maximum temperature recommended by the
manufacturer for your pool liner (seek advice from a pool maintenance technician).
AUTOMATIC (Full Inverter):
This mode allows you to set a target temperature and POOLICAN will automatically select the ope-
rating mode in order to maintain the temperature within +/- 2°C of the target. Temperature range
between 3°C and 40°C; by default the target temperature is 28°C. This mode can ensure that you do
not exceed the maximum temperature recommended by the manufacturer for your pool liner (seek
advice from a pool maintenance technician).
The Full Inverter system allows the power consumed by the Heat Pump (HP) to be adjusted depen-
ding on the desired temperature. During the heating phase, the HP will use its full available power
until the target temperature is reached, and then enter a temperature maintenance phase where it
will automatically regulate its power consumption.
In each of these modes, the target temperature to be reached can be set by pressing the
up and down arrows. The HP will maintain the temperature within +/- 2°C of the target.
By default, the temperature is displayed in °C (Celsius) and the green light will
be displayed; otherwise the unit of temperature is °F (Fahrenheit)
When the heat pump is in use, it may automatically switch to an evaporator defrosting phase to
ensure optimal performance. During this defrosting phase, the defrosting light
This phase is a normal part of operation and will automatically terminate. If required, this function
can be activated manually on the application.
In order to effectively manage the temperature throughout the day, when the heat pump is opera-
ting in one of the modes listed above, the circulation pump will also remain on 24/7.
+
should be reduced, and chlorine
C9
will turn green.
EN
| 19
loading