Dometic NDS SL12-100 Guía Rápida página 9

Gestor 12 dc link manager
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
CAUTION! Damage hazard
All cables of power connections must have a minimum cross-section of 25 mm², or in any case, the cross-
section must be matched to the required length of the cable.
5. Connect the starting battery positive
Fig. 
on page 4
6. Install and tighten the three M6 nuts.
7.
Loosen the two pin terminal screws.
CAUTION! Damage hazard
To prevent damage to the equipment, the house battery negative must be connected at the end of the in-
stallation.
8. Connect the D+ signal wire to pin
Fig. 
on page 5
9.
Tighten the two pin terminal screws.
NOTE If the device is connected correctly, it should emit an acoustic signal.
10. If the device does not emit an acoustic signal, press the On/Off switch.
Fig. 
on page 5
11. Install the lid and secure it with the two screws.
12. If the vehicle is equipped with a smart alternator (Euro-6), bridge connectors
cable.
Fig. 
on page 6
NOTE Connecting the jumper cable to either of the two connectors activates the smart alternator
mode.
7 Operation
The device is operating automatically without any user interactions required.
Operation with engine running
During the trip, when the alternator is operating, the device establishes a direct power supply line between the in-
verter and the starting battery. This allows the use of the air conditioner of the living side, the coffee machine and all
the other appliances without stressing the vehicle charging system. This also keeps the batteries safe from deep dis-
charges. When the engine is idling, or the vehicle accessories are operating, the voltage supplied by the alternator
drops and the device activates the economy mode. In this mode the compressor of the air conditioner is switched off
via a relay on the control connector. When the power supply from the alternator is restored, the device reactivates
the compressor. If even in this condition the alternator fails to meet all energy requirements, the power supply from
the house battery is directed to the inverter. When the alternator voltage returns back to optimal voltage range, the
power supply is switched back to the starting battery and the air conditioning compressor is reactivated, turning off
the economy function.
, the inverter positive
and the house battery negative wire to pin
and the house battery positive cables
.
and
with the supplied jumper
    EN
.
9
loading