LiftMaster MAXUM JDC Serie Manual De Instalación página 34

Operadores industriales de cc ejes de unión, elevador y carro de cc para puertas
Idiomas disponibles

Idiomas disponibles

Programming (continued)
Determine Operating Mode
Read the descriptions of the different wiring types
to determine which setting will be correct for each
application. Once the wiring type is determined, set the
selector dial accordingly.
LIFTMASTER MONITORED ENTRAPMENT PROTECTION
(LMEP) DEVICE IS REQUIRED
A LiftMaster Monitored Entrapment Protection Device is
required for the following wiring types.
B2
Momentary contact to open, close and stop, plus wiring
for sensing device to reverse and auxiliary devices to
open and close with open override. Programmable mid
stop available with this wiring type. Compatible with
3-Button Station, 1-Button Station, 1 and 3-Button
Remote Control.
B2 / T
Momentary contact to open, close, and stop, with open
override and Timer-To-Close. Every device that causes
the door to open, except any sensing edge input device,
activates the Timer-To-Close. Auxiliary controls can be
connected to open input to activate the Timer-To-Close.
If the Timer-To-Close has been activated, the open button
and radio control can recycle the timer. The stop button
will deactivate the timer until the next command input.
The Timer-To-Close will function from the programmable
mid stop with this wiring type. Compatible with 3-Button
Station,1-Button Station and 1 and 3-Button Remote
Control.
NOTE: Programmable "Car Dealer Mode" available.
B2 / TS
This mode will attempt to close the door from any
position except when fully closed, or when a Entrapment
Protection input is present. The stop button will not
disable the Timer-To-Close at any position. To disable
the Timer-To-Close in this mode, installation of a defeat
switch is required (see "Wiring Diagram" section).
Momentary contact to open, close, and stop with open
override and Timer-To-Close. Every device that causes
door to open, including a reversing device, activates the
Timer-To-Close. Auxiliary controls can be connected to
open input to activate the Timer-To-Close. If the timer
has been activated, the open button and radio control
can recycle the timer. The Timer-To-Close will function
from the programmable mid stop with this wiring type.
Compatible with 3-Button Station, 1-Button Station and 1
and 3-Button Remote Control.
NOTE: A Programmable "Car Dealer Mode" available.
FSTS
Momentary button contact for open, close and stop
programming. User set mid stop. User set Timer-To-Close.
The single button station opens the door to the full open
limit bypassing the mid stop and activates the
Timer-To-Close, putting the operator in B2/TS mode until
the door reaches the down limit, or is stopped in travel. At
which time the operator enters the B2 mode. Compatible
with 3-Button Station, 1-Button Station, 1 and 3-Button
Remote Control. A 1-Button remote control in FSTS
mode will open only with the Timer-To-Close, bypassing a
programmed mid stop. The Timer-To-Close will reset and
reverse when closing.
LIFTMASTER MONITORED ENTRAPMENT PROTECTION
DEVICE IS RECOMMENDED.
A LiftMaster Entrapment Protection Device is
recommended for the following wiring types.
C2
Momentary contact to open and stop with constant
pressure to close, open override plus wiring for sensing
device to reverse. Programmable mid stop available with
this wiring type. Compatible with 3-Button Station and
1-Button Station.
E2
Momentary contact to open with override and constant
pressure to close. Release of close button will cause
door to reverse (roll-back feature) plus wiring for sensing
device to reverse. Compatible with 3-Button Station.
D1
Constant pressure to open and close with wiring for
sensing device to stop. Compatible with 2 or 3-Button
Station.
IMPORTANT NOTES:
1. External interlocks may be used with all functional
modes.
2. Auxiliary devices are any devices that have only dry
contacts. Examples: loop detector, pneumatic or
electrical treadles, radio controls, one button stations,
pull cords, etc.
3. Open override means that the door may be reversed
while closing by activating an opening device without
the need to use the stop button first.
4. When the door is in a stopped position other than
fully closed,and an LMEP or EDGE input is activated,
the Restricted Close(RC) feature will allow a close
command when the close button is pressed and held.
The operator will begin closing after 5seconds. If the
close button is released the door will stop.
When in E2 mode, the door will move to the fully open
position.
34
loading